L'édition de cet ISBN n'est malheureusement plus disponible.
Afficher les exemplaires de cette édition ISBN
Frais de port :
EUR 23
De Allemagne vers Etats-Unis
Description du livre Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book extrapolates on waste energy from the exhaust of the gas turbine, due to great availability of energy and high temperature in this source . A thermodynamic analysis for a double effect absorption refrigeration cycle using exhaust gas turbine as a source of energy has been carried out, the binary mixture considered in the cycle was LiBr-H2O.The simulation is performed to estimate the effect of generator temperature ,ambient temperature ,absorber temperature and evaporator temperature on the coefficient of performance of system( COP ).The basic parameters at various state points of the cycle was computed using formulas of mathematical modeling by F.L.Lansing . The analysis has been done by varying evaporator temperature (Te) from 1-7 °C, ambient temperature from (Tamb) 30-45 °C and generator temperature (Tg) from 90-120 °C. The optimized results, corresponding to our study are : Tamb=30°C, Te=7°C, And Tg =95°C, Cop=1.44. 64 pp. Englisch. N° de réf. du vendeur 9783659917110
Description du livre Etat : New. N° de réf. du vendeur 26394692458
Description du livre Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book extrapolates on waste energy from the exhaust of the gas turbine, due to great availability of energy and high temperature in this source . A thermodynamic analysis for a double effect absorption refrigeration cycle using exhaust gas turbine as a source of energy has been carried out, the binary mixture considered in the cycle was LiBr-H2O.The simulation is performed to estimate the effect of generator temperature ,ambient temperature ,absorber temperature and evaporator temperature on the coefficient of performance of system( COP ).The basic parameters at various state points of the cycle was computed using formulas of mathematical modeling by F.L.Lansing . The analysis has been done by varying evaporator temperature (Te) from 1-7 °C, ambient temperature from (Tamb) 30-45 °C and generator temperature (Tg) from 90-120 °C. The optimized results, corresponding to our study are : Tamb=30°C, Te=7°C, And Tg =95°C, Cop=1.44. N° de réf. du vendeur 9783659917110
Description du livre Paperback. Etat : Brand New. 64 pages. 8.66x5.91x0.15 inches. In Stock. N° de réf. du vendeur zk3659917117
Description du livre Etat : New. Print on Demand. N° de réf. du vendeur 401684661
Description du livre Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Mahmmud Alzu bi YousefYousef Mahmmud Al-zu bi born on October,18th,1992 ,Jerash. He had been to Al-qabsi Secondary School. He received his Bsc degree in Mechanical Engineering from Jordan University of Science and Technology. He is. N° de réf. du vendeur 158606662