L'édition de cet ISBN n'est malheureusement plus disponible.
Afficher les exemplaires de cette édition ISBN
Frais de port :
EUR 3,69
Vers Etats-Unis
Description du livre Etat : New. N° de réf. du vendeur ABLIING23Apr0316110074067
Description du livre PAP. Etat : New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. N° de réf. du vendeur L0-9783836486095
Description du livre Etat : New. PRINT ON DEMAND Book; New; Fast Shipping from the UK. No. book. N° de réf. du vendeur ria9783836486095_lsuk
Description du livre PF. Etat : New. N° de réf. du vendeur 6666-IUK-9783836486095
Description du livre Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Due to the pronounced dose gradients generated by proton beams, proton treatment plans can be very sensitive to treatment uncertainties. However in IMPT many different solutions of the inverse problem exist which result in dose distributions of comparable quality. This thesis investigates methods to exploit this degeneracy of solutions to generate treatment plans which are robust to uncertainties. To rate the sensitivity to uncertainties of individual beamlet dose distributions the heterogeneity number H was developed. It was shown that H correlates with the dose calculation error introduced by the commonly employed pencil beam algorithm as well as with the sensitivity to setup errors of individual beamlets. Finally, the 'worst case optimization' was developed to account for uncertainties during the inverse treatment planning. This technique was applied to account for range uncertainties, setup errors and a combination of both uncertainties. The treatment plans generated with this new optimization method are much more robust to the respective uncertainties as conventional IMPT and even as conventional single-field proton treatment plans. 100 pp. Deutsch. N° de réf. du vendeur 9783836486095
Description du livre Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Due to the pronounced dose gradients generated by proton beams, proton treatment plans can be very sensitive to treatment uncertainties. However in IMPT many different solutions of the inverse problem exist which result in dose distributions of comparable quality. This thesis investigates methods to exploit this degeneracy of solutions to generate treatment plans which are robust to uncertainties. To rate the sensitivity to uncertainties of individual beamlet dose distributions the heterogeneity number H was developed. It was shown that H correlates with the dose calculation error introduced by the commonly employed pencil beam algorithm as well as with the sensitivity to setup errors of individual beamlets. Finally, the 'worst case optimization' was developed to account for uncertainties during the inverse treatment planning. This technique was applied to account for range uncertainties, setup errors and a combination of both uncertainties. The treatment plans generated with this new optimization method are much more robust to the respective uncertainties as conventional IMPT and even as conventional single-field proton treatment plans. N° de réf. du vendeur 9783836486095
Description du livre PAP. Etat : New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. N° de réf. du vendeur L0-9783836486095
Description du livre Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Due to the pronounced dose gradients generated by proton beams, proton treatment plans can be very sensitive to treatment uncertainties. However in IMPT many different solutions of the inverse problem exist which result in dose distributions of comparable q. N° de réf. du vendeur 5388928
Description du livre N° de réf. du vendeur STOCK12770406