Masonry walls are not isotropic; they have less strength in bending in the vertical direction than in the horizontal. The design of two-way spanning masonry panels under lateral loads is therefore complicated and tedious.
The design tables in this book present a straightforward and practical approach to the design of rectangular lateral loaded panels under uniformly distributed loads. The tables give the ultimate load capacity of masonry panels of different sizes, properties and edge conditions. They cover both unreinforced and bed joint reinforced masonry panels. The basis of the preparation of the design tables is that presented in BS 5628 Part 1: 1992 and Part 2: 1995.
The load tables will improve the efficiency of the design process and be a considerable asset to the practising engineer.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
EUR 72 expédition depuis Belgique vers Etats-Unis
Destinations, frais et délaisEUR 3,41 expédition vers Etats-Unis
Destinations, frais et délaisVendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. pp. 56. N° de réf. du vendeur 26457315
Quantité disponible : 1 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. pp. 56. N° de réf. du vendeur 7423420
Quantité disponible : 1 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. pp. 56. N° de réf. du vendeur 18457321
Quantité disponible : 1 disponible(s)
Vendeur : PBShop.store UK, Fairford, GLOS, Royaume-Uni
PAP. Etat : New. New Book. Shipped from UK. Established seller since 2000. N° de réf. du vendeur FW-9780727725264
Quantité disponible : 1 disponible(s)
Vendeur : Rarewaves USA, OSWEGO, IL, Etats-Unis
Paperback. Etat : New. Masonry walls are not isotropic; they have less strength in bending in the vertical direction than in the horizontal. The design of two-way spanning masonry panels under lateral loads is therefore complicated and tedious.The design tables in this book present a straightforward and practical approach to the design of rectangular lateral loaded panels under uniformly distributed loads. The tables give the ultimate load capacity of masonry panels of different sizes, properties and edge conditions. They cover both unreinforced and bed joint reinforced masonry panels. The basis of the preparation of the design tables is that presented in BS 5628 Part 1: 1992 and Part 2: 1995.The load tables will improve the efficiency of the design process and be a considerable asset to the practising engineer. N° de réf. du vendeur LU-9780727725264
Quantité disponible : 1 disponible(s)
Vendeur : Ria Christie Collections, Uxbridge, Royaume-Uni
Etat : New. In. N° de réf. du vendeur ria9780727725264_new
Quantité disponible : 1 disponible(s)
Vendeur : THE SAINT BOOKSTORE, Southport, Royaume-Uni
Paperback / softback. Etat : New. New copy - Usually dispatched within 4 working days. 218. N° de réf. du vendeur B9780727725264
Quantité disponible : 1 disponible(s)
Vendeur : Kennys Bookshop and Art Galleries Ltd., Galway, GY, Irlande
Etat : New. N° de réf. du vendeur V9780727725264
Quantité disponible : 1 disponible(s)
Vendeur : Kennys Bookstore, Olney, MD, Etats-Unis
Etat : New. N° de réf. du vendeur V9780727725264
Quantité disponible : 1 disponible(s)
Vendeur : Revaluation Books, Exeter, Royaume-Uni
Paperback. Etat : Brand New. 1996 edition. 56 pages. 11.42x7.95x0.31 inches. In Stock. N° de réf. du vendeur __0727725262
Quantité disponible : 1 disponible(s)