This report addresses Generic Safety Issue (GSI) 188, "Steam Generator Tube Leaks or Ruptures Concurrent with Containment Bypass from Main Steam Line or Feedwater Line Breaches," which concerns the potential for additional tube leakage or ruptures from the growth of existing cracks in steam generator tubes resulting from the dynamic loads following a main steam line break (MSLB) or feedwater line break (FWLB). To address the issue, this report provides the technical findings from thermal-hydraulic transient analyses and sensitivity studies, a simplified finite-element model of steam generator support structures and tubes, and structural analyses and sensitivity studies of the potential for crack growth. The results show that the additional dynamic loads from an MSLB are greater than those from an FWLB. The report concludes that dynamic loads from an MSLB are low and do not affect the structural integrity of tubes and do not lead to additional leakage or ruptures beyond what would be determined using differential pressure loads alone. Therefore, GSI-188 is closed, and the staff recommends no changes to existing regulations or guidance with respect to the dynamic loads induced by a breach of the main steam or feedwater line.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : New. N° de réf. du vendeur 19032516-n
Quantité disponible : Plus de 20 disponibles
Vendeur : BargainBookStores, Grand Rapids, MI, Etats-Unis
Paperback or Softback. Etat : New. Resolution of Generic Safety Issue 188: Steam Generator Tube Leaks or Ruptures Concurrent with Containment Bypass from Main Steam Line or Feedwater Li. Book. N° de réf. du vendeur BBS-9781249920120
Quantité disponible : 5 disponible(s)
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 19032516
Quantité disponible : Plus de 20 disponibles
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand pp. 32. N° de réf. du vendeur 393513170
Quantité disponible : 4 disponible(s)
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. Print on Demand pp. 32. N° de réf. du vendeur 26386086669
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND pp. 32. N° de réf. du vendeur 18386086663
Quantité disponible : 4 disponible(s)
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 19032516
Quantité disponible : Plus de 20 disponibles
Vendeur : THE SAINT BOOKSTORE, Southport, Royaume-Uni
Paperback / softback. Etat : New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days. N° de réf. du vendeur C9781249920120
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : New. N° de réf. du vendeur 19032516-n
Quantité disponible : Plus de 20 disponibles
Vendeur : moluna, Greven, Allemagne
Etat : New. KlappentextThis report addresses Generic Safety Issue (GSI) 188, Steam Generator Tube Leaks or Ruptures Concurrent with Containment Bypass from Main Steam Line or Feedwater Line Breaches, which concerns the potential for additional tub. N° de réf. du vendeur 6491098
Quantité disponible : Plus de 20 disponibles