Corrosion under insulation (CUI) refers to the external corrosion of piping and vessels that occurs underneath externally clad/jacketed insulation as a result of the penetration of water. By its very nature CUI tends to remain undetected until the insulation and cladding/jacketing is removed to allow inspection or when leaks occur. CUI is a common problem shared by the refining, petrochemical, power, industrial, onshore and offshore industries.
The European Federation of Corrosion (EFC) Working Parties WP13 and WP15 have worked to provide guidelines on managing CUI together with a number of major European refining, petrochemical and offshore companies including BP, Chevron-Texaco, Conoco-Phillips, ENI, Exxon-Mobil, IFP, MOL, Scanraff, Statoil, Shell, Total and Borealis. The guidelines within this document are intended for use on all plants and installations that contain insulated vessels, piping, and equipment. The guidelines cover a risk-based inspection methodology for CUI, inspection techniques (including non-destructive evaluation methods) and recommended best practice for mitigating CUI, including design of plants and equipment, coatings, the use of thermal spray techniques, types of insulation, cladding/jacketing materials, and protection guards. The guidelines also include case studies.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Corrosion under insulation (CUI) refers to the external corrosion of piping and vessels that occurs underneath externally clad/jacketed insulation as a result of the penetration of water. By its very nature CUI tends to remain undetected until the insulation and cladding/jacketing is removed to allow inspection or when leaks occur. CUI is a common problem shared by the refining, petrochemical, power, industrial, onshore and offshore industries.
The European Federation of Corrosion (EFC) Working Parties WP13 and WP15 have worked to provide guidelines on managing CUI together with a number of major European refining, petrochemical and offshore companies including BP, Chevron-Texaco, Conoco-Phillips, ENI, Exxon-Mobil, IFP, MOL, Scanraff, Statoil, Shell, Total and Borealis. The guidelines within this document are intended for use on all plants and installations that contain insulated vessels, piping, and equipment. The guidelines cover a risk-based inspection methodology for CUI, inspection techniques (including non-destructive evaluation methods) and recommended best practice for mitigating CUI, including design of plants and equipment, coatings, the use of thermal spray techniques, types of insulation, cladding/jacketing materials, and protection guards. The guidelines also include case studies.
Dr Stefan Winnik is Managing Director of SW Materials and Corrosion Ltd.; he was formerly with the ExxonMobil chemical company in the UK.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : Goodwill of Greater Milwaukee and Chicago, Racine, WI, Etats-Unis
Etat : good. Book is considered to be in good or better condition. The actual cover image may not match the stock photo. Hard cover books may show signs of wear on the spine, cover or dust jacket. Paperback book may show signs of wear on spine or cover as well as having a slight bend, curve or creasing to it. Book should have minimal to no writing inside and no highlighting. Pages should be free of tears or creasing. Stickers should not be present on cover or elsewhere, and any CD or DVD expected with the book is included. Book is not a former library copy. N° de réf. du vendeur SEWV.1420076035.G
Quantité disponible : 1 disponible(s)
Vendeur : Buchpark, Trebbin, Allemagne
Etat : Sehr gut. Zustand: Sehr gut | Sprache: Englisch | Produktart: Bücher | Keine Beschreibung verfügbar. N° de réf. du vendeur 4043627/2
Quantité disponible : 1 disponible(s)