In cats anesthetized lightly with pentobarbital or alpha-chloralose, electrical stimulation of the paramedian lobule of cerebellum resulted in a change of EEG pattern. Prior to stimulation the pattern consisted of h igh-ampl itude slow waves with superimposed low-ampl itude fast activity. In addition, the EEGs of animals anesthetized with chloralose showed "chloralose spikes". Immediately following brief cerebellar stimulation the slow wave activity and spikes disappeared, leaving only low-voltage fast activity. The effect was most pronounced in the contralateral leads from the rostral portions of the cerebrum. Study of the parameters most effective in evoking this effect revealed that stimulation frequency, train duration, and probably pulse duration affected the duration of suppression in a sigmoid fashion, with inflection points at approximately 90 Hz, 2.5 sec, and 1 msec, respectively. Above threshold values, stimulation cur- rent showed an approximately linear relationship to duration of EEG sup- pression. The after-discharge resulting from focal electrical stimulation of the cerebral cortex could be shortened by electrical stimulation of the para- median lobule. The effect was essentially the same when cerebellar stim- ulation preceded, occurred during, or followed the cerebral cortical stim- ulation. The great variability of the after-discharge resulting from cerebral cortical stimulation as well as the variability of the effects of cerebellar stimulation made it impractical to study systematically the parameters op- timal for shorten ing after-discharge. Such a study wi II require use of an awake, preferably partially restrained animal with electrodes chronically implanted.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : Basi6 International, Irving, TX, Etats-Unis
Etat : Brand New. New. US edition. Print on demand title. Delivery takes 20-25 days. Excellent Customer Service. N° de réf. du vendeur POD-97173
Quantité disponible : Plus de 20 disponibles
Vendeur : Ria Christie Collections, Uxbridge, Royaume-Uni
Etat : New. In. N° de réf. du vendeur ria9781461345107_new
Quantité disponible : Plus de 20 disponibles
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. pp. 416. N° de réf. du vendeur 2697813154
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand pp. 416 67:B&W 6.69 x 9.61 in or 244 x 170 mm (Pinched Crown) Perfect Bound on White w/Gloss Lam. N° de réf. du vendeur 94584189
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND pp. 416. N° de réf. du vendeur 1897813160
Quantité disponible : 4 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. In cats anesthetized lightly with pentobarbital or alpha-chloralose, electrical stimulation of the paramedian lobule of cerebellum resulted in a change of EEG pattern. Prior to stimulation the pattern consisted of h igh-ampl itude slow waves with superimpos. N° de réf. du vendeur 4192850
Quantité disponible : Plus de 20 disponibles
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. Neuware - In cats anesthetized lightly with pentobarbital or alpha-chloralose, electrical stimulation of the paramedian lobule of cerebellum resulted in a change of EEG pattern. Prior to stimulation the pattern consisted of h igh-ampl itude slow waves with superimposed low-ampl itude fast activity. In addition, the EEGs of animals anesthetized with chloralose showed 'chloralose spikes'. Immediately following brief cerebellar stimulation the slow wave activity and spikes disappeared, leaving only low-voltage fast activity. The effect was most pronounced in the contralateral leads from the rostral portions of the cerebrum. Study of the parameters most effective in evoking this effect revealed that stimulation frequency, train duration, and probably pulse duration affected the duration of suppression in a sigmoid fashion, with inflection points at approximately 90 Hz, 2.5 sec, and 1 msec, respectively. Above threshold values, stimulation cur rent showed an approximately linear relationship to duration of EEG sup pression. The after-discharge resulting from focal electrical stimulation of the cerebral cortex could be shortened by electrical stimulation of the para median lobule. The effect was essentially the same when cerebellar stim ulation preceded, occurred during, or followed the cerebral cortical stim ulation. The great variability of the after-discharge resulting from cerebral cortical stimulation as well as the variability of the effects of cerebellar stimulation made it impractical to study systematically the parameters op timal for shorten ing after-discharge. Such a study wi II require use of an awake, preferably partially restrained animal with electrodes chronically implanted. N° de réf. du vendeur 9781461345107
Quantité disponible : 2 disponible(s)