The National Institute of Standards and Technology supplies calibrated photodiode standards and special tests of photodetectors for absolute spectral responsivity from 200 nm to 1800 nm. (This service will soon be expanded to 20 μm in the infrared.) The scale of absolute spectral responsivity is based solely on detector measurements traceable to the High Accuracy Cryogenic Radiometer maintained by the National Institute of Standards and Technology. Silicon photodiode light-trapping detectors are used to transfer the optical power unit from this cryogenic radiometer to monochromator-based facilities where routine measurements are performed. The transfer also involves modeling the quantum efficiency of the silicon photodiode light-trapping detectors. A description of current measurement services is given along with the procedures, equipment, and techniques used to perform these calibrations. Detailed estimates and procedures for determining uncertainties of the reported values are also presented.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
The National Institute of Standards and Technology supplies calibrated photodiode standards and special tests of photodetectors for absolute spectral responsivity from 200 nm to 1800 nm. (This service will soon be expanded to 20 μm in the infrared.) The scale of absolute spectral responsivity is based solely on detector measurements traceable to the High Accuracy Cryogenic Radiometer maintained by the National Institute of Standards and Technology. Silicon photodiode light-trapping detectors are used to transfer the optical power unit from this cryogenic radiometer to monochromator-based facilities where routine measurements are performed. The transfer also involves modeling the quantum efficiency of the silicon photodiode light-trapping detectors. A description of current measurement services is given along with the procedures, equipment, and techniques used to perform these calibrations. Detailed estimates and procedures for determining uncertainties of the reported values are also presented.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 21026072
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 21026072
Quantité disponible : Plus de 20 disponibles
Vendeur : THE SAINT BOOKSTORE, Southport, Royaume-Uni
Paperback / softback. Etat : New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days. N° de réf. du vendeur C9781495920608
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : New. N° de réf. du vendeur 21026072-n
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : New. N° de réf. du vendeur 21026072-n
Quantité disponible : Plus de 20 disponibles
Vendeur : CitiRetail, Stevenage, Royaume-Uni
Paperback. Etat : new. Paperback. The National Institute of Standards and Technology supplies calibrated photodiode standards and special tests of photodetectors for absolute spectral responsivity from 200 nm to 1800 nm. (This service will soon be expanded to 20 mm in the infrared.) The scale of absolute spectral responsivity is based solely on detector measurements traceable to the High Accuracy Cryogenic Radiometer maintained by the National Institute of Standards and Technology. Silicon photodiode light-trapping detectors are used to transfer the optical power unit from this cryogenic radiometer to monochromator-based facilities where routine measurements are performed. The transfer also involves modeling the quantum efficiency of the silicon photodiode light-trapping detectors. A description of current measurement services is given along with the procedures, equipment, and techniques used to perform these calibrations. Detailed estimates and procedures for determining uncertainties of the reported values are also presented. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability. N° de réf. du vendeur 9781495920608
Quantité disponible : 1 disponible(s)