Sixteen reference commercial buildings were defined by the U.S. Department of Energy (DOE) and created as EnergyPlus input files. They were developed for use in assessing new technologies and supporting the development of energy codes. Infiltration rates were inputs to the models, rather than calculated based on established building airflow theory. In order to support more physically-based airflow calculations, as well as contaminant transport analysis, models of the 16 reference buildings were created in the multizone airflow and contaminant program CONTAM. A number of key inputs had to be defined for the CONTAM models, including changes to the interior zoning to account for more realistic airflows. Annual airflow and contaminant simulations were performed in CONTAM for six of the buildings. As expected, the assumed infiltration rates in EnergyPlus did not realistically reflect impacts of indoor-outdoor weather conditions. In contrast, there were clear relationships between the air change rates calculated by CONTAM and weather. The infiltration rates assumed in EnergyPlus were also generally lower than those calculated by CONTAM. Contaminant analyses were also performed for occupant-generated carbon dioxide and volatile organic compounds from indoor sources, as well as for outdoor particulate matter and ozone.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Sixteen reference commercial buildings were defined by the U.S. Department of Energy (DOE) and created as EnergyPlus input files. They were developed for use in assessing new technologies and supporting the development of energy codes. Infiltration rates were inputs to the models, rather than calculated based on established building airflow theory. In order to support more physically-based airflow calculations, as well as contaminant transport analysis, models of the 16 reference buildings were created in the multizone airflow and contaminant program CONTAM. A number of key inputs had to be defined for the CONTAM models, including changes to the interior zoning to account for more realistic airflows. Annual airflow and contaminant simulations were performed in CONTAM for six of the buildings. As expected, the assumed infiltration rates in EnergyPlus did not realistically reflect impacts of indoor-outdoor weather conditions. In contrast, there were clear relationships between the air change rates calculated by CONTAM and weather. The infiltration rates assumed in EnergyPlus were also generally lower than those calculated by CONTAM. Contaminant analyses were also performed for occupant-generated carbon dioxide and volatile organic compounds from indoor sources, as well as for outdoor particulate matter and ozone.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 21160427
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : New. N° de réf. du vendeur 21160427-n
Quantité disponible : Plus de 20 disponibles
Vendeur : California Books, Miami, FL, Etats-Unis
Etat : New. Print on Demand. N° de réf. du vendeur I-9781496128454
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 21160427
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : New. N° de réf. du vendeur 21160427-n
Quantité disponible : Plus de 20 disponibles
Vendeur : THE SAINT BOOKSTORE, Southport, Royaume-Uni
Paperback / softback. Etat : New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days. N° de réf. du vendeur C9781496128454
Quantité disponible : Plus de 20 disponibles