This report provides key results of a six-month feasibility study on the effects of normal aging on the performance of pressure transmitters in nuclear power plants. Using experimental methods for response time testing of transmitters and aging tests on representative transmitters, the authors found that five reasonably effective methods are available for response time testing of pressure transmitters, two of which provide on-line measurement capability. The authors show that 38 percent of the problems reported in the 1,325 cases of the U.S. NRC's Licensee Event Report database over a nine-year period involved potential age-related cases such as calibration shifts and response time degradation.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
This report provides key results of a six-month feasibility study on the effects of normal aging on the performance of pressure transmitters in nuclear power plants. Using experimental methods for response time testing of transmitters and aging tests on representative transmitters, the authors found that five reasonably effective methods are available for response time testing of pressure transmitters, two of which provide on-line measurement capability. The authors show that 38 percent of the problems reported in the 1,325 cases of the U.S. NRC's Licensee Event Report database over a nine-year period involved potential age-related cases such as calibration shifts and response time degradation.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 21606325
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 21606325
Quantité disponible : Plus de 20 disponibles
Vendeur : THE SAINT BOOKSTORE, Southport, Royaume-Uni
Paperback / softback. Etat : New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days. N° de réf. du vendeur C9781499140118
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : New. N° de réf. du vendeur 21606325-n
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : New. N° de réf. du vendeur 21606325-n
Quantité disponible : Plus de 20 disponibles
Vendeur : CitiRetail, Stevenage, Royaume-Uni
Paperback. Etat : new. Paperback. This report provides key results of a six-month feasibility study on the effects of normal aging on the performance of pressure transmitters in nuclear power plants. Using experimental methods for response time testing of transmitters and aging tests on representative transmitters, the authors found that five reasonably effective methods are available for response time testing of pressure transmitters, two of which provide on-line measurement capability. The authors show that 38 percent of the problems reported in the 1,325 cases of the U.S. NRC's Licensee Event Report database over a nine-year period involved potential age-related cases such as calibration shifts and response time degradation. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability. N° de réf. du vendeur 9781499140118
Quantité disponible : 1 disponible(s)