ABSTRACT Dry storage cask designs for spent nuclear fuel are submitted to the U.S. Nuclear Regulatory Commission (NRC) for certification under Title 10 of the Code of Federal Regulations (10 CFR) Part 72, “Licensing Requirements for the Independent Storage of Spent Nuclear Fuel, High- Level Radioactive Waste, and Reactor-Related Greater Than Class C Waste.” The NRC staff technical review of these designs is performed in accordance with 10 CFR Part 72 and the “Standard Review Plan (SRP) for Spent Fuel Dry Storage Systems at a General License Facility” (NUREG-1536, 2010). To ensure that the cask and fuel material temperatures of the dry cask storage system will remain within the allowable limits or criteria for normal, off-normal, and accident conditions, a thermal review is performed as part of the application’s technical review. Recent applications increasingly have used thermal-hydraulic analyses and computational fluid dynamics (CFD) codes (e.g., FLUENT) to demonstrate the adequacy of the thermal design. Therefore, in cooperation with the Division of Spent Fuel Storage and Transportation of the Office of Nuclear Material Safety and Safeguards, the Office of Nuclear Regulatory Research developed this guide to provide practical advice for reviewing CFD methods used in vendor applications and for achieving high-quality CFD simulations of a dry cask. To assist in the analysis, the report includes procedures, analysis methods, and acceptable assumptions.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : New. N° de réf. du vendeur 21499040-n
Quantité disponible : Plus de 20 disponibles
Vendeur : California Books, Miami, FL, Etats-Unis
Etat : New. Print on Demand. N° de réf. du vendeur I-9781499636215
Quantité disponible : Plus de 20 disponibles
Vendeur : Lucky's Textbooks, Dallas, TX, Etats-Unis
Etat : New. N° de réf. du vendeur ABLIING23Mar2716030247927
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 21499040
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 21499040
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : New. N° de réf. du vendeur 21499040-n
Quantité disponible : Plus de 20 disponibles
Vendeur : THE SAINT BOOKSTORE, Southport, Royaume-Uni
Paperback / softback. Etat : New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days 447. N° de réf. du vendeur C9781499636215
Quantité disponible : Plus de 20 disponibles
Vendeur : CitiRetail, Stevenage, Royaume-Uni
Paperback. Etat : new. Paperback. ABSTRACT Dry storage cask designs for spent nuclear fuel are submitted to the U.S. Nuclear Regulatory Commission (NRC) for certification under Title 10 of the Code of Federal Regulations (10 CFR) Part 72, "Licensing Requirements for the Independent Storage of Spent Nuclear Fuel, High- Level Radioactive Waste, and Reactor-Related Greater Than Class C Waste." The NRC staff technical review of these designs is performed in accordance with 10 CFR Part 72 and the "Standard Review Plan (SRP) for Spent Fuel Dry Storage Systems at a General License Facility" (NUREG-1536, 2010). To ensure that the cask and fuel material temperatures of the dry cask storage system will remain within the allowable limits or criteria for normal, off-normal, and accident conditions, a thermal review is performed as part of the application's technical review. Recent applications increasingly have used thermal-hydraulic analyses and computational fluid dynamics (CFD) codes (e.g., FLUENT) to demonstrate the adequacy of the thermal design. Therefore, in cooperation with the Division of Spent Fuel Storage and Transportation of the Office of Nuclear Material Safety and Safeguards, the Office of Nuclear Regulatory Research developed this guide to provide practical advice for reviewing CFD methods used in vendor applications and for achieving high-quality CFD simulations of a dry cask. To assist in the analysis, the report includes procedures, analysis methods, and acceptable assumptions. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability. N° de réf. du vendeur 9781499636215
Quantité disponible : 1 disponible(s)