Articles liés à DYNAMIC ANALYSIS OF BASE ISOLATED TUBULAR TALL BUILDING...

DYNAMIC ANALYSIS OF BASE ISOLATED TUBULAR TALL BUILDING SYSTEM (LEAD RUBBER BEARING) IN ETABS - Couverture souple

 
9781691370689: DYNAMIC ANALYSIS OF BASE ISOLATED TUBULAR TALL BUILDING SYSTEM (LEAD RUBBER BEARING) IN ETABS

Synopsis

When seismic forces occurred due to earth motion, a huge loss of life has occurred. Various technics have been made and also working to develop the techniques and design methods to mitigate the effect of earthquake on high or low rise structures. Theseismic base isolation and tubular system is passive techniques effectively used by in building structues.it shifts the time period of structure from predominant frequency range of seismic forces and also reduce the storey drift and floor acceleration.In case of dynamic analysis of tall buildings, the various important dynamic characteristics of tall building namely, the natural frequency (ω,radians/second) or simply time period(T,seconds),lateral displacement, base shear and overturning moment of tall buildings using ETABS software. In this paper, an approximate procedure is generated to perform the seismic analysis of simple and tubular tall building system with base isolation (lead-rubber bearings) system and the outcome compared with the results obtained without base isolation (lead-rubber bearing) of tall buildings. Base isolation system is basically a passive control device which decouples the super structure from substructure resting ground motion by insinuating structural elements with low horizontal stiffness between the structure and foundation. This analysis of G+29 rigid joint plane RCC frames for four cases. First case is simple RCC frame with fixed base and with base isolation (LRB), second case is simple tube RCC frame with fixed base and with base isolation (LRB), third case is tube in tube system RCC frame with fixed base and with base isolation (LRB) and fourth case is bundle tube system RCC frame with fixed base and with base isolation (LRB) .The effectiveness of base isolation in every cases is compared with simple frame and tubular system cases. This analysis is done by using ETABS software and for design purpose of base isolated system 1893:2002 (part 1) and for seismic design of isolated structures (F.Naeim and J.M.Kelly).

Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.

Acheter neuf

Afficher cet article
EUR 16,32

Autre devise

EUR 11,56 expédition depuis Royaume-Uni vers France

Destinations, frais et délais

Résultats de recherche pour DYNAMIC ANALYSIS OF BASE ISOLATED TUBULAR TALL BUILDING...

Image d'archives

SINGH, Er AAMIR RIYAZ DAR & Er. SIMRANJIT
Edité par Independently published, 2019
ISBN 10 : 1691370681 ISBN 13 : 9781691370689
Neuf Paperback

Vendeur : Revaluation Books, Exeter, Royaume-Uni

Évaluation du vendeur 5 sur 5 étoiles Evaluation 5 étoiles, En savoir plus sur les évaluations des vendeurs

Paperback. Etat : Brand New. 48 pages. 11.69x8.27x0.12 inches. In Stock. N° de réf. du vendeur 1691370681

Contacter le vendeur

Acheter neuf

EUR 16,32
Autre devise
Frais de port : EUR 11,56
De Royaume-Uni vers France
Destinations, frais et délais

Quantité disponible : 1 disponible(s)

Ajouter au panier