Data centers consume roughly 1% of the total electricity demand, while ICT as a whole consumes around 10%. Demand is growing exponentially and, left unchecked, will grow to an estimated increase of 20% or more by 2030.
This book covers the energy consumption and minimization of the different data center components when running real workloads, taking into account the types of instructions executed by the servers. It presents the different air- and liquid-cooled technologies for servers and data centers with some real examples, including waste heat reuse through adsorption chillers, as well as the hardware and software used to measure, model and control energy. It computes and compares the Power Usage Effectiveness and the Total Cost of Ownership of new and existing data centers with different cooling designs, including free cooling and waste heat reuse leading to the Energy Reuse Effectiveness. The book concludes by demonstrating how a well-designed data center reusing waste heat to produce chilled water can reduce energy consumption by roughly 50%, and how renewable energy can be used to create net-zero energy data centers.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Luigi Brochard was a Distinguished Engineer at IBM, then at Lenovo Data Center Group where he designed energy aware software systems. He is now a consultant on energy efficiency.
Vinod Kamath worked with IBMx86 as a thermal engineer and is now a Senior Technical Staff Member with the Lenovo Data Center Group, where he is responsible for the water-cooled server design.
Julita Corbalán is Associate Professor at the UPB, associate researcher at BSC-CNS and technical leader for the EAR Lenovo-BSC project.
Scott Holland is a thermal engineer with Lenovo Data Center Group and is responsible for providing direct liquid-cooling solutions. His most recent project was the Lenovo ThinkSystem SD650.
Walter Mittelbach has been working on adsorption chillers at Fraunhofer ISE since 1995. He also founded two companies: Fahrenheit GmbH (2002) and Sorption Technologies GmbH (2018).
Michael Ott is a senior researcher in the HPC division at Leibniz Supercomputing Centre, where he leads the research activities on energy efficiency.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
EUR 61,50 expédition depuis Allemagne vers Etats-Unis
Destinations, frais et délaisEUR 5,76 expédition depuis Royaume-Uni vers Etats-Unis
Destinations, frais et délaisVendeur : Studibuch, Stuttgart, Allemagne
hardcover. Etat : Gut. Seiten; 9781786301857.3 Gewicht in Gramm: 1. N° de réf. du vendeur 738340
Quantité disponible : 1 disponible(s)
Vendeur : PBShop.store UK, Fairford, GLOS, Royaume-Uni
HRD. Etat : New. New Book. Shipped from UK. Established seller since 2000. N° de réf. du vendeur FW-9781786301857
Quantité disponible : 15 disponible(s)
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : New. N° de réf. du vendeur 33400302-n
Quantité disponible : Plus de 20 disponibles
Vendeur : Grand Eagle Retail, Bensenville, IL, Etats-Unis
Hardcover. Etat : new. Hardcover. Data centers consume roughly 1% of the total electricity demand, while ICT as a whole consumes around 10%. Demand is growing exponentially and, left unchecked, will grow to an estimated increase of 20% or more by 2030. This book covers the energy consumption and minimization of the different data center components when running real workloads, taking into account the types of instructions executed by the servers. It presents the different air- and liquid-cooled technologies for servers and data centers with some real examples, including waste heat reuse through adsorption chillers, as well as the hardware and software used to measure, model and control energy. It computes and compares the Power Usage Effectiveness and the Total Cost of Ownership of new and existing data centers with different cooling designs, including free cooling and waste heat reuse leading to the Energy Reuse Effectiveness. The book concludes by demonstrating how a well-designed data center reusing waste heat to produce chilled water can reduce energy consumption by roughly 50%, and how renewable energy can be used to create net-zero energy data centers. Shipping may be from multiple locations in the US or from the UK, depending on stock availability. N° de réf. du vendeur 9781786301857
Quantité disponible : 1 disponible(s)
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : New. N° de réf. du vendeur 33400302-n
Quantité disponible : Plus de 20 disponibles
Vendeur : Ria Christie Collections, Uxbridge, Royaume-Uni
Etat : New. In. N° de réf. du vendeur ria9781786301857_new
Quantité disponible : Plus de 20 disponibles
Vendeur : California Books, Miami, FL, Etats-Unis
Etat : New. N° de réf. du vendeur I-9781786301857
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 33400302
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 33400302
Quantité disponible : Plus de 20 disponibles
Vendeur : THE SAINT BOOKSTORE, Southport, Royaume-Uni
Hardback. Etat : New. New copy - Usually dispatched within 4 working days. 726. N° de réf. du vendeur B9781786301857
Quantité disponible : Plus de 20 disponibles