This book presents an innovative concept for designing a 400 kV double circuit composite tower. The major challenges encountered by the authors in the electrical design process of the composite tower are addressed. They concern material selection for the full composite cross-arm core, electrical insulation of the cross-arm, electrical dimensioning of the full composite tower, lightning shielding performance and failure of the full composite tower. The electric field performance of the tower's insulation has been investigated theoretically by using finite element method and experimentally by testing different fiber reinforced polymers as candidates. The book reports in detail those finite element simulations and tests, together with the authors' recommendations on the most suitable materials and manufacturing process as well as conductor clamp designs for the cross-arm. Another important issue of the full composite tower, which concerns the environmental aspects of the full composite tower, has also been evaluated. This book offers a timely reference guide on a highly innovative topic, addressing researchers working on power transmission system both in industry and academia.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : Universitätsbuchhandlung Herta Hold GmbH, Berlin, Allemagne
xi, 249 p. Hardcover. Einband bestoßen, daher Mängelexemplar gestempelt, sonst sehr guter Zustand. Imperfect copy due to slightly bumped cover, apart from this in very good condition. Stamped. Sprache: Englisch. N° de réf. du vendeur 9311JB
Quantité disponible : 3 disponible(s)
Vendeur : Brook Bookstore On Demand, Napoli, NA, Italie
Etat : new. Questo è un articolo print on demand. N° de réf. du vendeur 6c49f5f809cd7b82fb984302cb3f46dd
Quantité disponible : Plus de 20 disponibles
Vendeur : Basi6 International, Irving, TX, Etats-Unis
Etat : Brand New. New. US edition. Print on demand title. Delivery takes 20-25 days. Excellent Customer Service. N° de réf. du vendeur POD-246125
Quantité disponible : 10 disponible(s)
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 35459197
Quantité disponible : 15 disponible(s)
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Buch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book presents an innovative concept for designing a 400 kV double circuit composite tower. The major challenges encountered by the authors in the electrical design process of the composite tower are addressed. They concern material selection for the full composite cross-arm core, electrical insulation of the cross-arm, electrical dimensioning of the full composite tower, lightning shielding performance and failure of the full composite tower. The electric field performance of the tower's insulation has been investigated theoretically by using finite element method and experimentally by testing different fiber reinforced polymers as candidates. The book reports in detail those finite element simulations and tests, together with the authors' recommendations on the most suitable materials and manufacturing process as well as conductor clamp designs for the cross-arm. Another important issue of the full composite tower, which concerns the environmental aspects of the full composite tower, has also been evaluated. This book offers a timely reference guide on a highly innovative topic, addressing researchers working on power transmission system both in industry and academia. 264 pp. Englisch. N° de réf. du vendeur 9783030178420
Quantité disponible : 2 disponible(s)
Vendeur : Ria Christie Collections, Uxbridge, Royaume-Uni
Etat : New. In. N° de réf. du vendeur ria9783030178420_new
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : New. N° de réf. du vendeur 35459197-n
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : New. N° de réf. du vendeur 35459197-n
Quantité disponible : 15 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Describes a complete design procedure for a novel 400-kV double-circuit composite towerIncludes important consideration for material selection, insulation design and dimensioningReports in detail on all theoretical and experimental r. N° de réf. du vendeur 279702690
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 35459197
Quantité disponible : Plus de 20 disponibles