In this research the cooling tower performance has been analyzed by varying air inlet parameters with different air inlet angles and by attaching a nozzle in air inlet. The cooling tower analyzed here is used specifically for small scale industries, which is forced draft counter-flow cooling tower with single module capacities from 10 to 100 cooling tons. In this research 50 tons cooling capacity model has been taken as reference model. The analysis has been done using computational fluid dynamics (CFD) FLUENT software. The cooling tower models have been modeled using SOLIDWORKS software and they have been meshed using ICEM CFD software. The meshed models have been analyzed using FLUENT software. The air inlet angles varied in horizontal direction, vertical direction and by combining both horizontal and vertical inclination. A convergent nozzle has been modeled and assembled to the inlet pipe. The temperature contours of the cooling tower models have been taken from the analysis. Based on the outlet cold water temperature, the improved effectiveness of the cooling tower model has been obtained.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In this research the cooling tower performance has been analyzed by varying air inlet parameters with different air inlet angles and by attaching a nozzle in air inlet. The cooling tower analyzed here is used specifically for small scale industries, which is forced draft counter-flow cooling tower with single module capacities from 10 to 100 cooling tons. In this research 50 tons cooling capacity model has been taken as reference model. The analysis has been done using computational fluid dynamics (CFD) FLUENT software. The cooling tower models have been modeled using SOLIDWORKS software and they have been meshed using ICEM CFD software. The meshed models have been analyzed using FLUENT software. The air inlet angles varied in horizontal direction, vertical direction and by combining both horizontal and vertical inclination. A convergent nozzle has been modeled and assembled to the inlet pipe. The temperature contours of the cooling tower models have been taken from the analysis. Based on the outlet cold water temperature, the improved effectiveness of the cooling tower model has been obtained. 72 pp. Englisch. N° de réf. du vendeur 9783330005792
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Mohamed Shameer Dr. P.Mohamed Shameer P. completed his PhD degree (Full Time) in MechanicalEngineering from Anna University Chennai, Tamil Nadu, India in 2017. Heis a former SENIOR RESEARCH FELLOW (SRF), awarded by Council ofScientif. N° de réf. du vendeur 385707119
Quantité disponible : Plus de 20 disponibles
Vendeur : Revaluation Books, Exeter, Royaume-Uni
Paperback. Etat : Brand New. 72 pages. 8.66x5.91x0.17 inches. In Stock. N° de réf. du vendeur 3330005793
Quantité disponible : 1 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -In this research the cooling tower performance has been analyzed by varying air inlet parameters with different air inlet angles and by attaching a nozzle in air inlet. The cooling tower analyzed here is used specifically for small scale industries, which is forced draft counter-flow cooling tower with single module capacities from 10 to 100 cooling tons. In this research 50 tons cooling capacity model has been taken as reference model. The analysis has been done using computational fluid dynamics (CFD) FLUENT software. The cooling tower models have been modeled using SOLIDWORKS software and they have been meshed using ICEM CFD software. The meshed models have been analyzed using FLUENT software. The air inlet angles varied in horizontal direction, vertical direction and by combining both horizontal and vertical inclination. A convergent nozzle has been modeled and assembled to the inlet pipe. The temperature contours of the cooling tower models have been taken from the analysis. Based on the outlet cold water temperature, the improved effectiveness of the cooling tower model has been obtained.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 72 pp. Englisch. N° de réf. du vendeur 9783330005792
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In this research the cooling tower performance has been analyzed by varying air inlet parameters with different air inlet angles and by attaching a nozzle in air inlet. The cooling tower analyzed here is used specifically for small scale industries, which is forced draft counter-flow cooling tower with single module capacities from 10 to 100 cooling tons. In this research 50 tons cooling capacity model has been taken as reference model. The analysis has been done using computational fluid dynamics (CFD) FLUENT software. The cooling tower models have been modeled using SOLIDWORKS software and they have been meshed using ICEM CFD software. The meshed models have been analyzed using FLUENT software. The air inlet angles varied in horizontal direction, vertical direction and by combining both horizontal and vertical inclination. A convergent nozzle has been modeled and assembled to the inlet pipe. The temperature contours of the cooling tower models have been taken from the analysis. Based on the outlet cold water temperature, the improved effectiveness of the cooling tower model has been obtained. N° de réf. du vendeur 9783330005792
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Analysis of Cooling Tower Performance Using Ansys Fluent Software | Approach on Effectiveness Inspection | P. Mohamed Shameer (u. a.) | Taschenbuch | 72 S. | Englisch | 2018 | LAP LAMBERT Academic Publishing | EAN 9783330005792 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 114738075
Quantité disponible : 5 disponible(s)