Due to environmental and economical constraints, it is difficult to build new power lines and to reinforce the existing ones. The continued growth in demand for electric power be met by increased loading of available lines. A consequence of this is reduction of power system damping, leading to a risk of poorly damped power oscillations between generators. This thesis proposes the use of controlled active and reactive power to increase damping of such electro-mechanical oscillations. The focus of this work is to analyze the dynamic performance of the Unified Power Flow Controller (UPFC). Reactive power compensation is a main predicament in the control of electric power system. Reactive power from the source increases the transmission losses and decreases the power transmission aptitude of the transmission lines. Reactive power must not be transmitted throughout the transmission line to a longer distance. Flexible AC Transmission Systems (FACTS) devices such as static compensator (STATCOM) unified power flow controller (UPFC) and static volt-ampere compensator (SVC) are worn to effortlessness these problems.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Due to environmental and economical constraints, it is difficult to build new power lines and to reinforce the existing ones. The continued growth in demand for electric power be met by increased loading of available lines. A consequence of this is reduction of power system damping, leading to a risk of poorly damped power oscillations between generators. This thesis proposes the use of controlled active and reactive power to increase damping of such electro-mechanical oscillations. The focus of this work is to analyze the dynamic performance of the Unified Power Flow Controller (UPFC). Reactive power compensation is a main predicament in the control of electric power system. Reactive power from the source increases the transmission losses and decreases the power transmission aptitude of the transmission lines. Reactive power must not be transmitted throughout the transmission line to a longer distance. Flexible AC Transmission Systems (FACTS) devices such as static compensator (STATCOM) unified power flow controller (UPFC) and static volt-ampere compensator (SVC) are worn to effortlessness these problems. 164 pp. Englisch. N° de réf. du vendeur 9783330007680
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Selvaperumal SundaramoorthyDr.S.Selvaperumal was born on 12th April, 1977 in his native town of virudhunagar. He is presently associated as Professor & Head (EEE) with Syed Ammal Engg. College, Ramanathapuram, TN, India. He has publi. N° de réf. du vendeur 158246860
Quantité disponible : Plus de 20 disponibles
Vendeur : Revaluation Books, Exeter, Royaume-Uni
Paperback. Etat : Brand New. 164 pages. 8.66x5.91x0.37 inches. In Stock. N° de réf. du vendeur 3330007680
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. DQ Model Based UPFC with Various Controllers | Sundaramoorthy Selvaperumal | Taschenbuch | 164 S. | Englisch | 2016 | LAP LAMBERT Academic Publishing | EAN 9783330007680 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 107938451
Quantité disponible : 5 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Due to environmental and economical constraints, it is difficult to build new power lines and to reinforce the existing ones. The continued growth in demand for electric power be met by increased loading of available lines. A consequence of this is reduction of power system damping, leading to a risk of poorly damped power oscillations between generators. This thesis proposes the use of controlled active and reactive power to increase damping of such electro-mechanical oscillations. The focus of this work is to analyze the dynamic performance of the Unified Power Flow Controller (UPFC). Reactive power compensation is a main predicament in the control of electric power system. Reactive power from the source increases the transmission losses and decreases the power transmission aptitude of the transmission lines. Reactive power must not be transmitted throughout the transmission line to a longer distance. Flexible AC Transmission Systems (FACTS) devices such as static compensator (STATCOM) unified power flow controller (UPFC) and static volt-ampere compensator (SVC) are worn to effortlessness these problems.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 164 pp. Englisch. N° de réf. du vendeur 9783330007680
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Due to environmental and economical constraints, it is difficult to build new power lines and to reinforce the existing ones. The continued growth in demand for electric power be met by increased loading of available lines. A consequence of this is reduction of power system damping, leading to a risk of poorly damped power oscillations between generators. This thesis proposes the use of controlled active and reactive power to increase damping of such electro-mechanical oscillations. The focus of this work is to analyze the dynamic performance of the Unified Power Flow Controller (UPFC). Reactive power compensation is a main predicament in the control of electric power system. Reactive power from the source increases the transmission losses and decreases the power transmission aptitude of the transmission lines. Reactive power must not be transmitted throughout the transmission line to a longer distance. Flexible AC Transmission Systems (FACTS) devices such as static compensator (STATCOM) unified power flow controller (UPFC) and static volt-ampere compensator (SVC) are worn to effortlessness these problems. N° de réf. du vendeur 9783330007680
Quantité disponible : 1 disponible(s)
Vendeur : Mispah books, Redhill, SURRE, Royaume-Uni
paperback. Etat : New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book. N° de réf. du vendeur ERICA82933300076806
Quantité disponible : 1 disponible(s)