The proposed device has been implemented in Cadence AMS 180 nm CMOS technology. Glucometer interface comprises of Transimpedance Amplifier (TIA), Instrumentation Amplifier(IA), RC filter. Our job is to design the analog block in the interface circuit. The basic block in the design is Operational amplifier which provides gain of 70dB with phase margin of 56 deg and gain bandwidth product of 33MHz. It is used in design of further stages. The work outlined in this project is towards developing a portable, economy blood glucose meter for self-monitoring of blood glucose, which has high performance with multifunction. The developed system prompts diabetics to measure their blood glucose regularly at home, and provides remote caregivers with complete patient information for diagnosis and tracking. This aids in the improvement in diabetes control.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Ch. Pavan Kumar has completed B.Tech and M.Tech from JNTUH and pursuing Ph.D from JNTUH, India, Presently working as Asst Prof in KITS Warangal. Dr.K.Sivani completed B.Tech from KU, Wgl and M.Tech from NIT Wgl India then PhD from JNTU, Hyderabad, India. Presently working as Professor in KITS wgl. Interesting fields are VLSI and Signal Processing.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
EUR 9,70 expédition depuis Allemagne vers France
Destinations, frais et délaisVendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Pavan Kumar ChinnalaCh. Pavan Kumar has completed B.Tech and M.Tech from JNTUH and pursuing Ph.D from JNTUH, India, Presently working as Asst Prof in KITS Warangal. Dr.K.Sivani completed B.Tech from KU, Wgl and M.Tech from NIT Wgl In. N° de réf. du vendeur 157321659
Quantité disponible : Plus de 20 disponibles
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The proposed device has been implemented in Cadence AMS 180 nm CMOS technology. Glucometer interface comprises of Transimpedance Amplifier (TIA), Instrumentation Amplifier(IA), RC filter. Our job is to design the analog block in the interface circuit. The basic block in the design is Operational amplifier which provides gain of 70dB with phase margin of 56 deg and gain bandwidth product of 33MHz. It is used in design of further stages. The work outlined in this project is towards developing a portable, economy blood glucose meter for self-monitoring of blood glucose, which has high performance with multifunction. The developed system prompts diabetics to measure their blood glucose regularly at home, and provides remote caregivers with complete patient information for diagnosis and tracking. This aids in the improvement in diabetes control. N° de réf. du vendeur 9783330342989
Quantité disponible : 1 disponible(s)
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The proposed device has been implemented in Cadence AMS 180 nm CMOS technology. Glucometer interface comprises of Transimpedance Amplifier (TIA), Instrumentation Amplifier(IA), RC filter. Our job is to design the analog block in the interface circuit. The basic block in the design is Operational amplifier which provides gain of 70dB with phase margin of 56 deg and gain bandwidth product of 33MHz. It is used in design of further stages. The work outlined in this project is towards developing a portable, economy blood glucose meter for self-monitoring of blood glucose, which has high performance with multifunction. The developed system prompts diabetics to measure their blood glucose regularly at home, and provides remote caregivers with complete patient information for diagnosis and tracking. This aids in the improvement in diabetes control. 64 pp. Englisch. N° de réf. du vendeur 9783330342989
Quantité disponible : 2 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. Neuware -The proposed device has been implemented in Cadence AMS 180 nm CMOS technology. Glucometer interface comprises of Transimpedance Amplifier (TIA), Instrumentation Amplifier(IA), RC filter. Our job is to design the analog block in the interface circuit. The basic block in the design is Operational amplifier which provides gain of 70dB with phase margin of 56 deg and gain bandwidth product of 33MHz. It is used in design of further stages. The work outlined in this project is towards developing a portable, economy blood glucose meter for self-monitoring of blood glucose, which has high performance with multifunction. The developed system prompts diabetics to measure their blood glucose regularly at home, and provides remote caregivers with complete patient information for diagnosis and tracking. This aids in the improvement in diabetes control.Books on Demand GmbH, Überseering 33, 22297 Hamburg 64 pp. Englisch. N° de réf. du vendeur 9783330342989
Quantité disponible : 2 disponible(s)
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26396955532
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18396955526
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 400470099
Quantité disponible : 4 disponible(s)
Vendeur : Revaluation Books, Exeter, Royaume-Uni
Paperback. Etat : Brand New. 64 pages. 8.66x5.91x0.15 inches. In Stock. N° de réf. du vendeur 3330342986
Quantité disponible : 1 disponible(s)