This study aimed to determine the optimum source to image distance (SID) for key radiographic projections, in diagnostic radiology. Three secondary aims were to determine the effect of changes in SID on the amount of scattered radiation at the image receptor, to determine the effect of changes in SID on the radiation dose to the patient and to assess any effects of changes in SID on the quality of the images. The study was performed using Monte Carlo simulation, employing EGSnrcMP and PCXMC. The Monte Carlo codes were benchmarked against independent experimental studies and shown to give excellent agreement. The conclusion was that for imaging of the trunk, other than the chest, the use of an SID of 150 cm will enable optimization of doses to patients. To optimize image quality and patient dose, a number of recommendations are made for technological improvements and for clinical practice.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Dr John Poletti has an MSc in Nuclear Physics from the University of Auckland, and a PhD in Radiology Physics from the University of Sydney. Formerly he was a Scientist at the National Radiation Laboratory in Christchurch, New Zealand. He is currently a Senior Lecturer at Unitec Institute of Technology, Auckland, New Zealand.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : moluna, Greven, Allemagne
Kartoniert / Broschiert. Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Poletti JohnDr John Poletti has an MSc in Nuclear Physics from the Universitynof Auckland, and a PhD in Radiology Physics from the Universitynof Sydney. Formerly he was a Scientist at the National RadiationnLaboratory in Christchurch. N° de réf. du vendeur 4960102
Quantité disponible : Plus de 20 disponibles
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This study aimed to determine the optimum source toimage distance (SID) for key radiographicprojections, in diagnostic radiology. Threesecondary aims were to determine the effect ofchanges in SID on the amount of scattered radiationat the image receptor, to determine the effect ofchanges in SID on the radiation dose to the patientand to assess any effects of changes in SID on thequality of the images. The study was performed usingMonte Carlo simulation, employing EGSnrcMP and PCXMC.The Monte Carlo codes were benchmarked againstindependent experimental studies and shown to giveexcellent agreement. The conclusion was that forimaging of the trunk, other than the chest, the useof an SID of 150 cm will enable optimization of dosesto patients. To optimize image quality and patientdose, a number of recommendations are made fortechnological improvements and for clinical practice. N° de réf. du vendeur 9783639129335
Quantité disponible : 2 disponible(s)
Vendeur : Books Puddle, Woodside, NY, Etats-Unis
Etat : New. pp. 200. N° de réf. du vendeur 26128749244
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand pp. 200 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam. N° de réf. du vendeur 131805539
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND pp. 200. N° de réf. du vendeur 18128749238
Quantité disponible : 4 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Optimisation of Source to Image Distance in Diagnostic Radiology | A study using Monte Carlo simulation | John Poletti | Taschenbuch | Englisch | VDM Verlag Dr. Müller | EAN 9783639129335 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 101646739
Quantité disponible : 5 disponible(s)
Vendeur : Mispah books, Redhill, SURRE, Royaume-Uni
Paperback. Etat : Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book. N° de réf. du vendeur ERICA79036391293346
Quantité disponible : 1 disponible(s)