The development of miniature ion trap mass spectrometers has been an active area, fueled by the promising analytical capabilities and the convenience of fast in situ analysis. The objective is to miniaturize mass spectrometers in weight, size, and power consumption while retaining the analytical capabilities of mass spectrometry at the same time. The book focuses on the instrumentation of miniature ion trap mass spectrometers, including ionization, ion transfer, mass analyzer, ion detection and related vacuum and electronic techniques. Two miniature mass spectrometers, a 10 kg Mini 10 with electron impact ionization source, developed in 2005 and a 5 kg Mini 11 with multiple ionization sources, developed in 2008, are introduced. The technical details of key components are discussed. Special focus is given to a glow discharge electron impact ionization source, which is an ideal substitute for the filament electron source used in the electron impact ionization, and a discontinuous atmospheric pressure interface, which enables the implementation of atmospheric pressure ionization sources in miniature ion trap mas spectrometers with limited pumping capabilities.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
The development of miniature ion trap mass spectrometers has been an active area, fueled by the promising analytical capabilities and the convenience of fast in situ analysis. The objective is to miniaturize mass spectrometers in weight, size, and power consumption while retaining the analytical capabilities of mass spectrometry at the same time. The book focuses on the instrumentation of miniature ion trap mass spectrometers, including ionization, ion transfer, mass analyzer, ion detection and related vacuum and electronic techniques. Two miniature mass spectrometers, a 10 kg Mini 10 with electron impact ionization source, developed in 2005 and a 5 kg Mini 11 with multiple ionization sources, developed in 2008, are introduced. The technical details of key components are discussed. Special focus is given to a glow discharge electron impact ionization source, which is an ideal substitute for the filament electron source used in the electron impact ionization, and a discontinuous atmospheric pressure interface, which enables the implementation of atmospheric pressure ionization sources in miniature ion trap mas spectrometers with limited pumping capabilities.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : New. N° de réf. du vendeur 8896657-n
Quantité disponible : Plus de 20 disponibles
Vendeur : BargainBookStores, Grand Rapids, MI, Etats-Unis
Paperback or Softback. Etat : New. Miniaturization of the Ion Trap Mass Spectrometer. Book. N° de réf. du vendeur BBS-9783639242263
Quantité disponible : 5 disponible(s)
Vendeur : PBShop.store US, Wood Dale, IL, Etats-Unis
PAP. Etat : New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. N° de réf. du vendeur L0-9783639242263
Quantité disponible : Plus de 20 disponibles
Vendeur : Rarewaves.com USA, London, LONDO, Royaume-Uni
Paperback. Etat : New. N° de réf. du vendeur LU-9783639242263
Quantité disponible : Plus de 20 disponibles
Vendeur : PBShop.store UK, Fairford, GLOS, Royaume-Uni
PAP. Etat : New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. N° de réf. du vendeur L0-9783639242263
Quantité disponible : Plus de 20 disponibles
Vendeur : Ria Christie Collections, Uxbridge, Royaume-Uni
Etat : New. In. N° de réf. du vendeur ria9783639242263_new
Quantité disponible : Plus de 20 disponibles
Vendeur : Chiron Media, Wallingford, Royaume-Uni
Paperback. Etat : New. N° de réf. du vendeur 6666-IUK-9783639242263
Quantité disponible : 10 disponible(s)
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : New. N° de réf. du vendeur 8896657-n
Quantité disponible : Plus de 20 disponibles
Vendeur : moluna, Greven, Allemagne
Kartoniert / Broschiert. Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Gao LiangLiang Gao received his BS and MS degree from the department of Precision Instruments and Mechanology at Tsinghua University in 2000 and 2003. He received his Ph.D. degree from the department of Chemistry at Purdue Univers. N° de réf. du vendeur 4970233
Quantité disponible : Plus de 20 disponibles
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The development of miniature ion trap mass spectrometers has been an active area, fueled by the promising analytical capabilities and the convenience of fast in situ analysis. The objective is to miniaturize mass spectrometers in weight, size, and power consumption while retaining the analytical capabilities of mass spectrometry at the same time. The book focuses on the instrumentation of miniature ion trap mass spectrometers, including ionization, ion transfer, mass analyzer, ion detection and related vacuum and electronic techniques. Two miniature mass spectrometers, a 10 kg Mini 10 with electron impact ionization source, developed in 2005 and a 5 kg Mini 11 with multiple ionization sources, developed in 2008, are introduced. The technical details of key components are discussed. Special focus is given to a glow discharge electron impact ionization source, which is an ideal substitute for the filament electron source used in the electron impact ionization, and a discontinuous atmospheric pressure interface, which enables the implementation of atmospheric pressure ionization sources in miniature ion trap mas spectrometers with limited pumping capabilities. N° de réf. du vendeur 9783639242263
Quantité disponible : 2 disponible(s)