The overvoltage protection performance of zinc oxide surge arresters under fast transient conditions is investigated in this work. Double impulse tests have been conducted on 15kV rated zinc oxide surge arresters to investigate impulse preconditioning effects on the zinc oxide protective characteristics. Test results show that the application of double impulses of similar shape and amplitudes with the same or opposite polarities and 10ms or longer time intervals has no significant effect on the protective performance. Impulse voltages and currents up to 6kA were used to test pairs of parallel-connected arresters with both matched and unmatched voltage-current characteristics. The current sharing performance of both matched and unmatched arresters improves as the current increases towards the rated value. The thermal differences between columns significantly change the current balance and may jeopardise the protective performance of multicolumn devices. Asymmetrical configuration has also been proved to affect the current balance in parallel arresters. Changes in the spark gap breakdown characteristics were observed when tested with the arrester in parallel.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : New. N° de réf. du vendeur 11502878-n
Quantité disponible : Plus de 20 disponibles
Vendeur : PBShop.store US, Wood Dale, IL, Etats-Unis
PAP. Etat : New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. N° de réf. du vendeur L0-9783639290578
Quantité disponible : Plus de 20 disponibles
Vendeur : Rarewaves.com USA, London, LONDO, Royaume-Uni
Paperback. Etat : New. N° de réf. du vendeur LU-9783639290578
Quantité disponible : Plus de 20 disponibles
Vendeur : PBShop.store UK, Fairford, GLOS, Royaume-Uni
PAP. Etat : New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. N° de réf. du vendeur L0-9783639290578
Quantité disponible : Plus de 20 disponibles
Vendeur : Ria Christie Collections, Uxbridge, Royaume-Uni
Etat : New. In. N° de réf. du vendeur ria9783639290578_new
Quantité disponible : Plus de 20 disponibles
Vendeur : Chiron Media, Wallingford, Royaume-Uni
Paperback. Etat : New. N° de réf. du vendeur 6666-IUK-9783639290578
Quantité disponible : 10 disponible(s)
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : New. N° de réf. du vendeur 11502878-n
Quantité disponible : Plus de 20 disponibles
Vendeur : moluna, Greven, Allemagne
Kartoniert / Broschiert. Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Abdul-Malek ZulkurnainZulkurnain Abdul-Malek was born in Malaysia in 1965. He obtained his B.E. from Monash University in 1989, MSc and PhD degrees from Cardiff University in 1995 and 1999 respectively. His research interests include. N° de réf. du vendeur 4974592
Quantité disponible : Plus de 20 disponibles
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The overvoltage protection performance of zinc oxide surge arresters under fast transient conditions is investigated in this work. Double impulse tests have been conducted on 15kV rated zinc oxide surge arresters to investigate impulse preconditioning effects on the zinc oxide protective characteristics. Test results show that the application of double impulses of similar shape and amplitudes with the same or opposite polarities and 10ms or longer time intervals has no significant effect on the protective performance. Impulse voltages and currents up to 6kA were used to test pairs of parallel-connected arresters with both matched and unmatched voltage-current characteristics. The current sharing performance of both matched and unmatched arresters improves as the current increases towards the rated value. The thermal differences between columns significantly change the current balance and may jeopardise the protective performance of multicolumn devices. Asymmetrical configuration has also been proved to affect the current balance in parallel arresters. Changes in the spark gap breakdown characteristics were observed when tested with the arrester in parallel. N° de réf. du vendeur 9783639290578
Quantité disponible : 2 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Fast Transient Response of High Voltage Surge Arresters | Characterisation of Zinc Oxide | Zulkurnain Abdul-Malek | Taschenbuch | Einband - flex.(Paperback) | Englisch | 2010 | VDM Verlag Dr. Müller | EAN 9783639290578 | Verantwortliche Person für die EU: OmniScriptum GmbH & Co. KG, Bahnhofstr. 28, 66111 Saarbrücken, info[at]akademikerverlag[dot]de | Anbieter: preigu. N° de réf. du vendeur 107312903
Quantité disponible : 5 disponible(s)