The use of pedicle screw as a fixation device for posterior spinal fusion surgery had become increasingly popular worldwide. Transpedicular screw fixation systems provide the most stability in an unstable spine and they are the only spinal fixation system that transfix all three spinal columns and resist spinal motion in all planes. An accurate knowledge of the pedicle osteometry is of utmost importance for a safe transpedicular screw placement. Improperly placed screw will lead to devastating neurological consequences to the patient especially in the thoracic spine. Thoracic transpedicular fixation is difficult in Asians because of the smaller size, variable pedicle entrance point, and more proximity to the spinal cord and neurovascular structures. Thoracic spinal surgery in Malaysia are performed based on the data of Caucasian population. Therefore, a complete database of the morphology of the thoracic vertebrae particularly the dimensions of thoracic pedicle is much needed to provide a safety margin in transpedicular fixation in our population. The results would also provide information for improvement in the design of pedicle screws suitable for the local population.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
The use of pedicle screw as a fixation device for posterior spinal fusion surgery had become increasingly popular worldwide. Transpedicular screw fixation systems provide the most stability in an unstable spine and they are the only spinal fixation system that transfix all three spinal columns and resist spinal motion in all planes. An accurate knowledge of the pedicle osteometry is of utmost importance for a safe transpedicular screw placement. Improperly placed screw will lead to devastating neurological consequences to the patient especially in the thoracic spine. Thoracic transpedicular fixation is difficult in Asians because of the smaller size, variable pedicle entrance point, and more proximity to the spinal cord and neurovascular structures. Thoracic spinal surgery in Malaysia are performed based on the data of Caucasian population. Therefore, a complete database of the morphology of the thoracic vertebrae particularly the dimensions of thoracic pedicle is much needed to provide a safety margin in transpedicular fixation in our population. The results would also provide information for improvement in the design of pedicle screws suitable for the local population.
Senior Lecturer & Orthopaedic Surgeon, Advanced Medical & Dental Institute, Universiti Sains Malaysia, Kepala Batas, Pulau Pinang, Malaysia.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : moluna, Greven, Allemagne
Kartoniert / Broschiert. Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Liau Kai MingSenior Lecturer & Orthopaedic Surgeon, Advanced Medical & Dental Institute, Universiti Sains Malaysia, Kepala Batas, Pulau Pinang, Malaysia.Autor/Autorin: Sooi Law KimSenior Lecturer & Orthopaedic Surgeon, A. N° de réf. du vendeur 4978123
Quantité disponible : Plus de 20 disponibles
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The use of pedicle screw as a fixation device for posterior spinal fusion surgery had become increasingly popular worldwide. Transpedicular screw fixation systems provide the most stability in an unstable spine and they are the only spinal fixation system that transfix all three spinal columns and resist spinal motion in all planes. An accurate knowledge of the pedicle osteometry is of utmost importance for a safe transpedicular screw placement. Improperly placed screw will lead to devastating neurological consequences to the patient especially in the thoracic spine. Thoracic transpedicular fixation is difficult in Asians because of the smaller size, variable pedicle entrance point, and more proximity to the spinal cord and neurovascular structures. Thoracic spinal surgery in Malaysia are performed based on the data of Caucasian population. Therefore, a complete database of the morphology of the thoracic vertebrae particularly the dimensions of thoracic pedicle is much needed to provide a safety margin in transpedicular fixation in our population. The results would also provide information for improvement in the design of pedicle screws suitable for the local population. N° de réf. du vendeur 9783639329162
Quantité disponible : 2 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. CROSS SECTIONAL STUDY OF THORACIC SPINE PEDICLE OSTEOMETRY | SAFETY MARGIN FOR PEDICLE SCREW FIXATION OF THORACIC SPINE IN MALAYSIAN POPULATION | Kai Ming Liau (u. a.) | Taschenbuch | Englisch | VDM Verlag Dr. Müller | EAN 9783639329162 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 106953160
Quantité disponible : 5 disponible(s)