As is probably the case with all successful innovations, the unique design of the thrust plate prosthesis (TPP) was not born of a sudden fancy for a radically different hip joint replacement, but emerged from elaborate biomechanical investigations on the loosening of conventional, intramedullarly anchored hip prosthesis shafts. In the 1970s, hip revisions due to loosening of the prostheses became a burden to patients not only physically and psychologically but also economically. This meant that it also became a matter of daily concern to the orthopaedic surgeon, who then had to cope with new, previously unknown problems. Loosening processes were de tected within 5 years of implantation in up to 25% of cases. While implant loosenings were considered to be the result of incorrect handling of materials, we felt that a number of details still had to be considered in regard to the behavior of the entire bone-prosthesis complex and the action of mechanical forces.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
The thrust plate prosthesis is a new type of hip prosthesis which maintains the physiological loading pattern of the bone. Experimental stress analysis of the proximal femur led to the development of this device, and clinical results over a period of more than 12 years confirm the sound biomechanical concept on which it is based. Conventional prostheses of the stem type are still prone to loosening and subsequent revision operations which are surgically particularly demanding. The thrust plate prosthesis, in contrast, allows a revision procedure, if at all necessary, to be performed with the same ease as a primary implantation. This, together with the fact that bone stock is preserved, makes it especially attractive for use in physiologically active and young patients. More than 150 figures, 16 of which are in colour, illustrate details in the development of the device and the clinical observations made by a group of participants in a pilot study. This book introduces the thrust plate prosthesis in detail to the hip surgeon. It is an accurate account of the long and laborious effort involved in realizing a project that was born out of critical observations.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : Brook Bookstore On Demand, Napoli, NA, Italie
Etat : new. Questo è un articolo print on demand. N° de réf. du vendeur 5QMFSFLPU7
Quantité disponible : Plus de 20 disponibles
Vendeur : Chiron Media, Wallingford, Royaume-Uni
PF. Etat : New. This item is printed on demand. Brand new book, sourced directly from publisher. Dispatch time is 6-7 days from our warehouse. Book will be sent in robust, secure packaging to ensure it reaches you securely. N° de réf. du vendeur 6666-IUK-9783642644337
Quantité disponible : 20 disponible(s)
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : New. N° de réf. du vendeur 19196425-n
Quantité disponible : 15 disponible(s)
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 19196425
Quantité disponible : 15 disponible(s)
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -As is probably the case with all successful innovations, the unique design of the thrust plate prosthesis (TPP) was not born of a sudden fancy for a radically different hip joint replacement, but emerged from elaborate biomechanical investigations on the loosening of conventional, intramedullarly anchored hip prosthesis shafts. In the 1970s, hip revisions due to loosening of the prostheses became a burden to patients not only physically and psychologically but also economically. This meant that it also became a matter of daily concern to the orthopaedic surgeon, who then had to cope with new, previously unknown problems. Loosening processes were de tected within 5 years of implantation in up to 25% of cases. While implant loosenings were considered to be the result of incorrect handling of materials, we felt that a number of details still had to be considered in regard to the behavior of the entire bone-prosthesis complex and the action of mechanical forces. 164 pp. Englisch. N° de réf. du vendeur 9783642644337
Quantité disponible : 2 disponible(s)
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : New. N° de réf. du vendeur 19196425-n
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 19196425
Quantité disponible : Plus de 20 disponibles
Vendeur : Revaluation Books, Exeter, Royaume-Uni
Paperback. Etat : Brand New. reprint edition. 160 pages. 9.00x6.00x0.40 inches. In Stock. N° de réf. du vendeur x-3642644333
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. As is probably the case with all successful innovations, the unique design of the thrust plate prosthesis (TPP) was not born of a sudden fancy for a radically different hip joint replacement, but emerged from elaborate biomechanical investigations on the lo. N° de réf. du vendeur 5066663
Quantité disponible : Plus de 20 disponibles
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. Druck auf Anfrage Neuware - Printed after ordering - As is probably the case with all successful innovations, the unique design of the thrust plate prosthesis (TPP) was not born of a sudden fancy for a radically different hip joint replacement, but emerged from elaborate biomechanical investigations on the loosening of conventional, intramedullarly anchored hip prosthesis shafts. In the 1970s, hip revisions due to loosening of the prostheses became a burden to patients not only physically and psychologically but also economically. This meant that it also became a matter of daily concern to the orthopaedic surgeon, who then had to cope with new, previously unknown problems. Loosening processes were de tected within 5 years of implantation in up to 25% of cases. While implant loosenings were considered to be the result of incorrect handling of materials, we felt that a number of details still had to be considered in regard to the behavior of the entire bone-prosthesis complex and the action of mechanical forces. N° de réf. du vendeur 9783642644337
Quantité disponible : 1 disponible(s)