Since 1958 the Association for the Study of Internal Fixation (ASIF) has worked to establish the experimental and biomechanical prin- ciples of the operative treatment of fractures. It has been proven that immediate, pain-free mobilization, made possible by stable internal fixation, is the key to restoring function in a fractured extremity. The same principles were applied in 1972173 by Roland Schmoker, who developed a universal plate and sophisticated instrument set designed initially for the treatment of comminuted fractures of the mandible. To extend the applications of his plate to reconstructions after ex- tensive tumor resections, he supplemented the device with tem- poromandibular joint prostheses and anchoring elements for the at- tachment of dentures. He first tested the functional stability of these implants experimentally in sheep. Later he found that the minipig had a more human-like jaw shape and masticatory action, and so he tested the implants in 37 mini pigs that underwent extensive mandibular re- sections without bone grafting, using sequential dye injections and postoperative weight gain to chart the progress of osseous regener- ation. Seven other animals were not operated and served as controls.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : Brook Bookstore On Demand, Napoli, NA, Italie
Etat : new. Questo è un articolo print on demand. N° de réf. du vendeur LIOVXP41HV
Quantité disponible : Plus de 20 disponibles
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Since 1958 the Association for the Study of Internal Fixation (ASIF) has worked to establish the experimental and biomechanical prin ciples of the operative treatment of fractures. It has been proven that immediate, pain-free mobilization, made possible by stable internal fixation, is the key to restoring function in a fractured extremity. The same principles were applied in 1972173 by Roland Schmoker, who developed a universal plate and sophisticated instrument set designed initially for the treatment of comminuted fractures of the mandible. To extend the applications of his plate to reconstructions after ex tensive tumor resections, he supplemented the device with tem poromandibular joint prostheses and anchoring elements for the at tachment of dentures. He first tested the functional stability of these implants experimentally in sheep. Later he found that the minipig had a more human-like jaw shape and masticatory action, and so he tested the implants in 37 mini pigs that underwent extensive mandibular re sections without bone grafting, using sequential dye injections and postoperative weight gain to chart the progress of osseous regener ation. Seven other animals were not operated and served as controls. 132 pp. Englisch. N° de réf. du vendeur 9783642717581
Quantité disponible : 2 disponible(s)
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : New. N° de réf. du vendeur 18762090-n
Quantité disponible : 15 disponible(s)
Vendeur : Ria Christie Collections, Uxbridge, Royaume-Uni
Etat : New. In. N° de réf. du vendeur ria9783642717581_new
Quantité disponible : Plus de 20 disponibles
Vendeur : Chiron Media, Wallingford, Royaume-Uni
PF. Etat : New. N° de réf. du vendeur 6666-IUK-9783642717581
Quantité disponible : 10 disponible(s)
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : New. N° de réf. du vendeur 18762090-n
Quantité disponible : Plus de 20 disponibles
Vendeur : moluna, Greven, Allemagne
Etat : New. N° de réf. du vendeur 5068871
Quantité disponible : Plus de 20 disponibles
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. pp. 132. N° de réf. du vendeur 2648028231
Quantité disponible : 4 disponible(s)
Vendeur : Revaluation Books, Exeter, Royaume-Uni
Paperback. Etat : Brand New. reprint edition. 132 pages. 9.40x6.60x0.50 inches. In Stock. N° de réf. du vendeur x-3642717586
Quantité disponible : 2 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Since 1958 the Association for the Study of Internal Fixation (ASIF) has worked to establish the experimental and biomechanical prin ciples of the operative treatment of fractures. It has been proven that immediate, pain-free mobilization, made possible by stable internal fixation, is the key to restoring function in a fractured extremity. The same principles were applied in 1972173 by Roland Schmoker, who developed a universal plate and sophisticated instrument set designed initially for the treatment of comminuted fractures of the mandible. To extend the applications of his plate to reconstructions after ex tensive tumor resections, he supplemented the device with tem poromandibular joint prostheses and anchoring elements for the at tachment of dentures. He first tested the functional stability of these implants experimentally in sheep. Later he found that the minipig had a more human-like jaw shape and masticatory action, and so he tested the implants in 37 mini pigs that underwent extensive mandibular re sections without bone grafting, using sequential dye injections and postoperative weight gain to chart the progress of osseous regener ation. Seven other animals were not operated and served as controls.Springer-Verlag KG, Sachsenplatz 4-6, 1201 Wien 132 pp. Englisch. N° de réf. du vendeur 9783642717581
Quantité disponible : 1 disponible(s)