Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, , course: Electrical engineering (Renewable energy), language: English, abstract: Wind electrical power systems are recently getting lot of attention, because they are cost competitive, environmental clean and safe renewable power source, as compared with fossil fuel and nuclear power generation. A special type of induction generator, called a doubly fed induction generator (DFIG), is used extensively for high-power wind applications. They are used more and more in wind turbine applications due to ease controllability, high energy efficiency and improved power quality. This thesis aims to develop a method of a field orientation scheme for control both the active and reactive powers of a DFIG driven by a wind turbine.The proposed control system consists of a wind turbine that drives a DFIG connected to the utility grid through AC-DC-AC link. The main control objective is to regulate the dc link voltage for operation at maximum available wind power.This is achieved by controlling the and axes components of voltages and currents for both rotor side and line side converters using PI controllers. The complete dynamic model of the proposed system is described in detail. Computer simulations have been carried out in order to validate the effectiveness of the proposed system during the variation of wind speed. The results prove that , better overall performances are achieved, quick recover from wind speed disturbances in addition to good tracking ability. Generally, any abnormalities associated with grid asymmetrical faults are going to affect the system performance considerably. During grid faults, unbalanced currents cause negative effects like overheating problems and mechanical stress due to high torque pulsations that can damage the rotor shaft, gearbox or blade assembly. Therefore, the dynamic model of the DFIG, driven by a wind turbine during grid faults has been analyzed and developed using the method of symmetrical components. The dynamic performance of the DFIG during unbalanced grid conditions is analyzed and described in detail using digital simulations. A novel fault ride-through (FRT) capability is proposed (i.e. the ability of the power system to remain connected to the grid during faults) with suitable control strategy in this thesis. In this scheme, the input mechanical energy of the wind turbine during grid faults is stored and utilized at the moment of fault clearance, instead of being dissipated in the resistors of the crowbar circuit as in the existing FRT schemes. [...]
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Personal Details: Name: Mahmoud abdel-Wahab Mossa Mohamed Date of Birth:1st, august, 1986. Place of Birth: Qena, Egypt. Nationality: Egyptian. Marital Status: Single. Major: Electrical Power and Machine Engineering. Employment: Teaching Assistant in Electrical Engineering Department, Faculty of Engineering, Minia University, Egypt. Since January 2010 till now. How To Contact: Address: - (Work): Electrical Engineering Department, Faculty of Engineering, Minia University, Egypt. - (Home): Quft, Qena, Egypt. Phone: - (Work): +2 (086) 2364510 - (Home): +2 (096) 6915181 Fax: +2 (086) 2346674 Mobile: +2 01229912291 E-mail: Eng_mahmoud2015@yahoo.com Education: May 2008 Faculty of Engineering, Minia University Minia - Egypt B.Sc., Electrical Engineering (Power & Machines) (Very Good, with honor, Ranked 84.75%) Graduation Project: "A DESIGN OF INDOOR AND OUTDOOR LIGHTING AND THE Electrical POWER DISTRIBUTION SYSTEM AND A STUDY FOR IT'S RELATED PROBLEMS. " (Distinction) January2013 Faculty of Engineering, Minia University Minia - Egypt Master in Electrical Engineering (Power & Machines) Thesis title: "Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults " Scientific Experience: -Publishing a research paper via multiscience publishing website, in wind engineering journal, with a title of '' Control of a Wind Driven DFIG Connected to the Grid Based on Field Orientation''. 1A.A. Hassan, 1Yehia S. Mohamed, 1A.M. El-Sawy, 1Mahmoud A. Mossa, Volume 35, Number 2, ISSN (10.1260/ 0309-524X. .35.2.127). -Publishing a research paper with a title of '' Enhancement of Fault Ride Through Capability of Wind Driven DFIG Connected to the Grid ''. 1Mahmoud A. Mossa, 1A.M. El-Sawy, Journal of Engineering Sciences, Assiut University, Vol. 40 No 2 pp. - March 2012. -Publishing a research paper via multiscience publishing website, in wind engineering journal, with a title of '' Novel Scheme for Improving the Performance of a Wind Driven DFIG During Grid Fault ''. 1Mahmoud A. Mossa, 1Yehia S.Mohamed, Volume 36, Number 3, ISSN (10.1260/0309-524X.36.3.305). -Publishing a research paper via WSEAS publishing academy, in WSEAS Transactions on Power Systems, with a title of '' Field Orientation Control of a Wind Driven DFIG Connected to the Grid ''. 1Mahmoud A. Mossa, Issue 4, Volume 7, October 2012, ISSN (2224-350X).
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : New. N° de réf. du vendeur 24362052-n
Quantité disponible : Plus de 20 disponibles
Vendeur : California Books, Miami, FL, Etats-Unis
Etat : New. N° de réf. du vendeur I-9783656368380
Quantité disponible : Plus de 20 disponibles
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, , course: Electrical engineering (Renewable energy), language: English, abstract: Wind electrical power systems are recently getting lot of attention, becausethey are cost competitive, environmental clean and safe renewable powersource, as compared with fossil fuel and nuclear power generation. A specialtype of induction generator, called a doubly fed induction generator (DFIG),is used extensively for high-power wind applications. They are used moreand more in wind turbine applications due to ease controllability, highenergy efficiency and improved power quality.This thesis aims to develop a method of a field orientation scheme forcontrol both the active and reactive powers of a DFIG driven by a windturbine.The proposed control system consists of a wind turbine that drives aDFIG connected to the utility grid through AC-DC-AC link. The maincontrol objective is to regulate the dc link voltage for operation at maximumavailable wind power.This is achieved by controlling the and axescomponents of voltages and currents for both rotor side and line sideconverters using PI controllers. The complete dynamic model of theproposed system is described in detail. Computer simulations have beencarried out in order to validate the effectiveness of the proposed systemduring the variation of wind speed. The results prove that , better overallperformances are achieved, quick recover from wind speed disturbances inaddition to good tracking ability.Generally, any abnormalities associated with grid asymmetrical faults aregoing to affect the system performance considerably. During grid faults,unbalanced currents cause negative effects like overheating problems andmechanical stress due to high torque pulsations that can damage the rotor shaft, gearbox or blade assembly. Therefore, the dynamic model of theDFIG, driven by a wind turbine during grid faults has been analyzed anddeveloped using the method of symmetrical components. The dynamicperformance of the DFIG during unbalanced grid conditions is analyzed anddescribed in detail using digital simulations.A novel fault ride-through (FRT) capability is proposed (i.e. the ability ofthe power system to remain connected to the grid during faults) with suitablecontrol strategy in this thesis. In this scheme, the input mechanical energy ofthe wind turbine during grid faults is stored and utilized at the moment offault clearance, instead of being dissipated in the resistors of the crowbarcircuit as in the existing FRT schemes. [.] 140 pp. Englisch. N° de réf. du vendeur 9783656368380
Quantité disponible : 2 disponible(s)
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : New. N° de réf. du vendeur 24362052-n
Quantité disponible : Plus de 20 disponibles
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand pp. 140. N° de réf. du vendeur 388939088
Quantité disponible : 4 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, , course: Electrical engineering (Renewable energy), language: English, abstract: Wind electrical power systems are recently getting lot of attention, becausethey are cost competitive, environmental clean and safe renewable powersource, as compared with fossil fuel and nuclear power generation. A specialtype of induction generator, called a doubly fed induction generator (DFIG)is used extensively for high-power wind applications. They are used moreand more in wind turbine applications due to ease controllability, highenergy efficiency and improved power quality.This thesis aims to develop a method of a field orientation scheme forcontrol both the active and reactive powers of a DFIG driven by a windturbine.The proposed control system consists of a wind turbine that drives aDFIG connected to the utility grid through AC-DC-AC link. The maincontrol objective is to regulate the dc link voltage for operation at maximumavailable wind power.This is achieved by controlling the and axescomponents of voltages and currents for both rotor side and line sideconverters using PI controllers. The complete dynamic model of theproposed system is described in detail. Computer simulations have beencarried out in order to validate the effectiveness of the proposed systemduring the variation of wind speed. The results prove that , better overallperformances are achieved, quick recover from wind speed disturbances inaddition to good tracking ability.Generally, any abnormalities associated with grid asymmetrical faults aregoing to affect the system performance considerably. During grid faultsunbalanced currents cause negative effects like overheating problems andmechanical stress due to high torque pulsations that can damage the rotor shaft, gearbox or blade assembly. Therefore, the dynamic model of theDFIG, driven by a wind turbine during grid faults has been analyzed anddeveloped using the method of symmetrical components. The dynamicperformance of the DFIG during unbalanced grid conditions is analyzed anddescribed in detail using digital simulations.A novel fault ride-through (FRT) capability is proposed (i.e. the ability ofthe power system to remain connected to the grid during faults) with suitablecontrol strategy in this thesis. In this scheme, the input mechanical energy ofthe wind turbine during grid faults is stored and utilized at the moment offault clearance, instead of being dissipated in the resistors of the crowbarcircuit as in the existing FRT schemes. [.]Books on Demand GmbH, Überseering 33, 22297 Hamburg 140 pp. Englisch. N° de réf. du vendeur 9783656368380
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. Druck auf Anfrage Neuware - Printed after ordering - Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, , course: Electrical engineering (Renewable energy), language: English, abstract: Wind electrical power systems are recently getting lot of attention, becausethey are cost competitive, environmental clean and safe renewable powersource, as compared with fossil fuel and nuclear power generation. A specialtype of induction generator, called a doubly fed induction generator (DFIG),is used extensively for high-power wind applications. They are used moreand more in wind turbine applications due to ease controllability, highenergy efficiency and improved power quality.This thesis aims to develop a method of a field orientation scheme forcontrol both the active and reactive powers of a DFIG driven by a windturbine.The proposed control system consists of a wind turbine that drives aDFIG connected to the utility grid through AC-DC-AC link. The maincontrol objective is to regulate the dc link voltage for operation at maximumavailable wind power.This is achieved by controlling the and axescomponents of voltages and currents for both rotor side and line sideconverters using PI controllers. The complete dynamic model of theproposed system is described in detail. Computer simulations have beencarried out in order to validate the effectiveness of the proposed systemduring the variation of wind speed. The results prove that , better overallperformances are achieved, quick recover from wind speed disturbances inaddition to good tracking ability.Generally, any abnormalities associated with grid asymmetrical faults aregoing to affect the system performance considerably. During grid faults,unbalanced currents cause negative effects like overheating problems andmechanical stress due to high torque pulsations that can damage the rotor shaft, gearbox or blade assembly. Therefore, the dynamic model of theDFIG, driven by a wind turbine during grid faults has been analyzed anddeveloped using the method of symmetrical components. The dynamicperformance of the DFIG during unbalanced grid conditions is analyzed anddescribed in detail using digital simulations.A novel fault ride-through (FRT) capability is proposed (i.e. the ability ofthe power system to remain connected to the grid during faults) with suitablecontrol strategy in this thesis. In this scheme, the input mechanical energy ofthe wind turbine during grid faults is stored and utilized at the moment offault clearance, instead of being dissipated in the resistors of the crowbarcircuit as in the existing FRT schemes. [.]. N° de réf. du vendeur 9783656368380
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults | Mahmoud Mossa | Taschenbuch | 140 S. | Englisch | 2013 | GRIN Verlag | EAN 9783656368380 | Verantwortliche Person für die EU: GRIN Publishing GmbH, Waltherstr. 23, 80337 München, info[at]grin[dot]com | Anbieter: preigu. N° de réf. du vendeur 106071926
Quantité disponible : 5 disponible(s)
Vendeur : GreatBookPricesUK, Woodford Green, Royaume-Uni
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 24362052
Quantité disponible : Plus de 20 disponibles
Vendeur : Mispah books, Redhill, SURRE, Royaume-Uni
Paperback. Etat : Like New. Like New. book. N° de réf. du vendeur ERICA75836563683846
Quantité disponible : 1 disponible(s)