Optical anisotropy effects can occur in building envelopes made of tempered glass. The visual effect has been neglected in the evaluation of the building product and increasingly leads to disputes between the parties involved. This thesis extends the state of knowledge on the cause and perception of optical anisotropic effects and presents a concept for measuring and evaluating them in flat monolithic tempered architectural glass.
Initially, an overview and description of current photoelastic measurement methods are given, and the accuracy of the used measurement setups is verified for the first time. The experimental basis for the concept is formed by extensive full-field retardation measurements in the laboratory and field studies of the maximum visibility of the anisotropy effects in an outdoor test rig with accompanying polarization measurements of the sky. Various glass types, geometries, and tempering levels are selected based on typically used products, and their influence on theresulting retardation image is investigated. Determining a correlation of the retardation images with the reflection images of selected test specimens in the outdoor test rig complements the experiments.
Based on this, digital evaluation methods are presented, further developed, and applied to the measured retardation images. From the critical analysis of these results, limit values for different anisotropy quality classes are derived, and the concept is complemented. With the implementation of the evaluation methods and the limit values in commercial anisotropy scanners, the quality of each glass pane can be determined directly after tempering in the future. By choosing the highest quality class A, it will be possible in the future to significantly reduce anisotropy effects in constructions made of tempered glass panes.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Steffen Dix, began his career at seele GmbH in 2003 as a technical draftsman apprentice. In 2015, he received a Master's degree in civil engineering with a focus on steel, lightweight, and glass construction from the University of Applied Sciences in Munich. During his studies from 2009 to 2015, he worked in the Labor für Stahl- und Leichtmetallbau, starting as a working student and later as a Research Assistant. His research focused on adhesives in façade design and the strength and quality of pre-stressed glass products, culminating in his dissertation on the measurement and evaluation of optical anisotropy effects in tempered architectural glass. From 2016 to 2022, he also worked as a freelance expert in glass and façade construction for the Ingenieurbüro für Bautechnik Schuler in Karlsruhe. Since 2022, the author is working as Technical Solution Manager at Josef Gartner GmbH (Permasteelisa), where he develops individual and innovative façade constructions.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : Brook Bookstore On Demand, Napoli, NA, Italie
Etat : new. Questo è un articolo print on demand. N° de réf. du vendeur YJNXNXBC0Z
Quantité disponible : Plus de 20 disponibles
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : As New. Unread book in perfect condition. N° de réf. du vendeur 46571172
Quantité disponible : 15 disponible(s)
Vendeur : GreatBookPrices, Columbia, MD, Etats-Unis
Etat : New. N° de réf. du vendeur 46571172-n
Quantité disponible : 15 disponible(s)
Vendeur : California Books, Miami, FL, Etats-Unis
Etat : New. N° de réf. du vendeur I-9783658420284
Quantité disponible : Plus de 20 disponibles
Vendeur : Ria Christie Collections, Uxbridge, Royaume-Uni
Etat : New. In English. N° de réf. du vendeur ria9783658420284_new
Quantité disponible : Plus de 20 disponibles
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Optical anisotropy e ects can occur in building envelopes made of tempered glass. The visual e ect has been neglected in the evaluation of the building product and increasingly leads to disputes between the parties involved. This thesis extends the state of knowledge on the cause and perception of optical anisotropic e ects and presents a concept for measuring and evaluating them in at monolithic tempered architectural glass.Initially, an overview and description of current photoelastic measurement methods are given, and the accuracy of the used measurement setups is verified for the first time. The experimental basis for the concept is formed by extensive full-field retardation measurements in the laboratory and field studies of the maximum visibility of the anisotropy e ects in an outdoor test rig with accompanying polarization measurements of the sky. Various glass types, geometries, and tempering levels are selected based on typically used products, and their in uence on theresulting retardation image is investigated. Determining a correlation of the retardation images with the re ection images of selected test specimens in the outdoor test rig complements the experiments.Based on this, digital evaluation methods are presented, further developed, and applied to the measured retardation images. From the critical analysis of these results, limit values for di erent anisotropy quality classes are derived, and the concept is complemented. With the implementation of the evaluation methods and the limit values in commercial anisotropy scanners, the quality of each glass pane can be determined directly after tempering in the future. By choosing the highest quality class A, it will be possible in the future to significantly reduce anisotropy e ects in constructions made of tempered glass panes. 168 pp. Englisch. N° de réf. du vendeur 9783658420284
Quantité disponible : 2 disponible(s)
Vendeur : Revaluation Books, Exeter, Royaume-Uni
Paperback. Etat : Brand New. 164 pages. 9.45x6.61x0.36 inches. In Stock. N° de réf. du vendeur x-3658420286
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Optical anisotropy e ects can occur in building envelopes made of tempered glass. The visual e ect has been neglected in the evaluation of the building product and increasingly leads to disputes between the parties involved. This thesis extends the state. N° de réf. du vendeur 881233902
Quantité disponible : Plus de 20 disponibles
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. Druck auf Anfrage Neuware - Printed after ordering - Optical anisotropy e ects can occur in building envelopes made of tempered glass. The visual e ect has been neglected in the evaluation of the building product and increasingly leads to disputes between the parties involved. This thesis extends the state of knowledge on the cause and perception of optical anisotropic e ects and presents a concept for measuring and evaluating them in at monolithic tempered architectural glass.Initially, an overview and description of current photoelastic measurement methods are given, and the accuracy of the used measurement setups is verified for the first time. The experimental basis for the concept is formed by extensive full-field retardation measurements in the laboratory and field studies of the maximum visibility of the anisotropy e ects in an outdoor test rig with accompanying polarization measurements of the sky. Various glass types, geometries, and tempering levels are selected based on typically used products, and their in uence on theresulting retardation image is investigated. Determining a correlation of the retardation images with the re ection images of selected test specimens in the outdoor test rig complements the experiments.Based on this, digital evaluation methods are presented, further developed, and applied to the measured retardation images. From the critical analysis of these results, limit values for di erent anisotropy quality classes are derived, and the concept is complemented. With the implementation of the evaluation methods and the limit values in commercial anisotropy scanners, the quality of each glass pane can be determined directly after tempering in the future. By choosing the highest quality class A, it will be possible in the future to significantly reduce anisotropy e ects in constructions made of tempered glass panes. N° de réf. du vendeur 9783658420284
Quantité disponible : 1 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Optical anisotropy e¿ects can occur in building envelopes made of tempered glass. The visual e¿ect has been neglected in the evaluation of the building product and increasingly leads to disputes between the parties involved. This thesis extends the state of knowledge on the cause and perception of optical anisotropic e¿ects and presents a concept for measuring and evaluating them in ¿at monolithic tempered architectural glass.Initially, an overview and description of current photoelastic measurement methods are given, and the accuracy of the used measurement setups is veri¿ed for the ¿rst time. The experimental basis for the concept is formed by extensive full-¿eld retardation measurements in the laboratory and ¿eld studies of the maximum visibility of the anisotropy e¿ects in an outdoor test rig with accompanying polarization measurements of the sky. Various glass types, geometries, and tempering levels are selected based on typically used products, and their in¿uence on theresulting retardation image is investigated. Determining a correlation of the retardation images with the re¿ection images of selected test specimens in the outdoor test rig complements the experiments.Based on this, digital evaluation methods are presented, further developed, and applied to the measured retardation images. From the critical analysis of these results, limit values for di¿erent anisotropy quality classes are derived, and the concept is complemented. With the implementation of the evaluation methods and the limit values in commercial anisotropy scanners, the quality of each glass pane can be determined directly after tempering in the future. By choosing the highest quality class A, it will be possible in the future to signi¿cantly reduce anisotropy e¿ects in constructions made of tempered glass panes.Springer-Verlag GmbH, Tiergartenstr. 17, 69121 Heidelberg 168 pp. Englisch. N° de réf. du vendeur 9783658420284
Quantité disponible : 1 disponible(s)