The determination of an accurate working length is one of the most critical steps of endodontic therapy. The radiographic method has been the standard means of determining the working length.Number of circumstances make this less than ideal method as it is impossible to consistently detect the major and minor foramina or cemento-dentinal junction (CDJ). Electronic root canal measuring devices were developed to reduce the number of radiographs during the treatment, improve the accuracy of the root canal measurement and to save time during the procedure. Many studies have shown that the current generation of electronic devices are accurate between 82-92% when compared to radiographically determined root canal lengths. A study was done evaluate the accuracy of working length determined using conventional radiograph followed by apex locator in the same tooth and comparing these findings post extraction with the natural apical constriction, after decalcifying the tooth. A stereomicroscope and image analysis unit was used to measure the differences and the results were tabulated and analyzed.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
The determination of an accurate working length is one of the most critical steps of endodontic therapy. The radiographic method has been the standard means of determining the working length.Number of circumstances make this less than ideal method as it is impossible to consistently detect the major and minor foramina or cemento-dentinal junction (CDJ). Electronic root canal measuring devices were developed to reduce the number of radiographs during the treatment, improve the accuracy of the root canal measurement and to save time during the procedure. Many studies have shown that the current generation of electronic devices are accurate between 82-92% when compared to radiographically determined root canal lengths. A study was done evaluate the accuracy of working length determined using conventional radiograph followed by apex locator in the same tooth and comparing these findings post extraction with the natural apical constriction, after decalcifying the tooth. A stereomicroscope and image analysis unit was used to measure the differences and the results were tabulated and analyzed.
Dr.Ashwini.P*Sr LecturerDr.Ashish ShettyProfessorDr.N.Meena,*Professorcontributing authorsDr.Usha.H.L*PrincipalDr.Santosh.R*ProfessorDr.Ashwin.D.P*ProfessorDr.Deepak Mehta*Associate profDr.Priya*Associate prof* V.S.Dental College and HospitalBangalore, India
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Santosh AshwiniDr.Ashwini.P*Sr LecturerDr.Ashish ShettyProfessorDr.N.Meena,*Professorcontributing authorsDr.Usha.H.L*PrincipalDr.Santosh.R*ProfessorDr.Ashwin.D.P*ProfessorDr.Deepak Mehta*Associate profDr.Priya*Associate prof* V.S.Den. N° de réf. du vendeur 5134437
Quantité disponible : Plus de 20 disponibles
Vendeur : Revaluation Books, Exeter, Royaume-Uni
Paperback. Etat : Brand New. 60 pages. 8.66x5.91x0.14 inches. In Stock. N° de réf. du vendeur 365914102X
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The determination of an accurate working length is one of the most critical steps of endodontic therapy. The radiographic method has been the standard means of determining the working length.Number of circumstances make this less than ideal method as it is impossible to consistently detect the major and minor foramina or cemento-dentinal junction (CDJ). Electronic root canal measuring devices were developed to reduce the number of radiographs during the treatment, improve the accuracy of the root canal measurement and to save time during the procedure. Many studies have shown that the current generation of electronic devices are accurate between 82-92% when compared to radiographically determined root canal lengths. A study was done evaluate the accuracy of working length determined using conventional radiograph followed by apex locator in the same tooth and comparing these findings post extraction with the natural apical constriction, after decalcifying the tooth. A stereomicroscope and image analysis unit was used to measure the differences and the results were tabulated and analyzed. N° de réf. du vendeur 9783659141027
Quantité disponible : 2 disponible(s)
Vendeur : Mispah books, Redhill, SURRE, Royaume-Uni
paperback. Etat : New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book. N° de réf. du vendeur ERICA829365914102X6
Quantité disponible : 1 disponible(s)