Shear connectors between concrete slabs and steel beams in composite constructions play an important role in the seismic response of a structure. Headed stud and Perfobond shear connectors are the most common types of shear connectors while the application of C-shaped shear connectors was increasing over the last decade. Since there are some limitations in the use of headed studs and Perfobond connectors, the use of C-shaped shear connectors is recommended. In this book, the behavior of C-shaped angle shear connectors embedded in high strength concrete are presented. The connectors were tested under monotonic and low cyclic fatigue loading. Investigations were conducted in order to consider several parameters affecting the performance of the angle shear connectors such as the connectors’ geometric properties and different concrete strength. The results of experimental push-out tests were used to verify the parametric investigations. Based on the results, angle shear connectors showed good behavior in terms of shear capacity but not in ductility as the main criterion for the behavior of shear connectors. The details of angle shear connector behavior have been discussed in details.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Shear connectors between concrete slabs and steel beams in composite constructions play an important role in the seismic response of a structure. Headed stud and Perfobond shear connectors are the most common types of shear connectors while the application of C-shaped shear connectors was increasing over the last decade. Since there are some limitations in the use of headed studs and Perfobond connectors, the use of C-shaped shear connectors is recommended. In this book, the behavior of C-shaped angle shear connectors embedded in high strength concrete are presented. The connectors were tested under monotonic and low cyclic fatigue loading. Investigations were conducted in order to consider several parameters affecting the performance of the angle shear connectors such as the connectors’ geometric properties and different concrete strength. The results of experimental push-out tests were used to verify the parametric investigations. Based on the results, angle shear connectors showed good behavior in terms of shear capacity but not in ductility as the main criterion for the behavior of shear connectors. The details of angle shear connector behavior have been discussed in details.
He was born in Baft, Iran in 1983. He earned his bachelor’s degree in civil engineering in IAU of Tehran, Iran in 2006 and his master degree in construction engineering in 2008 from the University Putra Malaysia. He continued his education at the University of Malaya, Malaysia and earned his Ph.D. in structural engineering and materials in 2013.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. pp. 116. N° de réf. du vendeur 26128172353
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand pp. 116 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam. N° de réf. du vendeur 131366558
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND pp. 116. N° de réf. du vendeur 18128172363
Quantité disponible : 4 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Shear connectors between concrete slabs and steel beams in composite constructions play an important role in the seismic response of a structure. Headed stud and Perfobond shear connectors are the most common types of shear connectors while the application of C-shaped shear connectors was increasing over the last decade. Since there are some limitations in the use of headed studs and Perfobond connectors, the use of C-shaped shear connectors is recommended. In this book, the behavior of C-shaped angle shear connectors embedded in high strength concrete are presented. The connectors were tested under monotonic and low cyclic fatigue loading. Investigations were conducted in order to consider several parameters affecting the performance of the angle shear connectors such as the connectors geometric properties and different concrete strength. The results of experimental push-out tests were used to verify the parametric investigations. Based on the results, angle shear connectors showed good behavior in terms of shear capacity but not in ductility as the main criterion for the behavior of shear connectors. The details of angle shear connector behavior have been discussed in details. N° de réf. du vendeur 9783659239601
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. N° de réf. du vendeur 5142219
Quantité disponible : Plus de 20 disponibles
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. C-Shaped Angle Shear Connectors in High Strength Concrete | Behavior of Shear Connectors in Composite Beam | Mahdi Shariati (u. a.) | Taschenbuch | Englisch | LAP Lambert Academic Publishing | EAN 9783659239601 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 105221744
Quantité disponible : 5 disponible(s)