The objectives of this study are to investigate and compare the dose distribution defined with divergent cerrobend alloy custom blocks to the distribution obtained with multileaf collimator (MLC) provided by high energy linear accelerator. The study was made for simple block replacement situations. Prior to making the comparison, multileaf collimator performance checks will be made. These checks include the following measurements: leaf Attenuation, leaf transmissions, in-between-leaf leakage properties and measurement of tongue and groove effect. By using of ionization chamber in water phantom, percent depth dose, beam flatness, symmetry, penumbra, leaf transmission and leakage will be measured. By using of radiographic films the transmission, penumbra, and verification of leaf position and leaf motion will be determined . Finally output factor of both multileaf collimator and cerrobend block will be measured same field sizes at the same conditions of dosimetry. The final aim of this study to improve the accuracy of cancer treatment delivery
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
The objectives of this study are to investigate and compare the dose distribution defined with divergent cerrobend alloy custom blocks to the distribution obtained with multileaf collimator (MLC) provided by high energy linear accelerator. The study was made for simple block replacement situations. Prior to making the comparison, multileaf collimator performance checks will be made. These checks include the following measurements: leaf Attenuation, leaf transmissions, in-between-leaf leakage properties and measurement of tongue and groove effect. By using of ionization chamber in water phantom, percent depth dose, beam flatness, symmetry, penumbra, leaf transmission and leakage will be measured. By using of radiographic films the transmission, penumbra, and verification of leaf position and leaf motion will be determined . Finally output factor of both multileaf collimator and cerrobend block will be measured same field sizes at the same conditions of dosimetry. The final aim of this study to improve the accuracy of cancer treatment delivery
Dr Ehab HegazyLecturer of physics Faculty of engineering Delta University of science and technology EgyptAcademic degree: PhD
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : moluna, Greven, Allemagne
Kartoniert / Broschiert. Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Hegazy EhabDr Ehab HegazyLecturer of physics Faculty of engineering Delta University of science and technology EgyptAcademic degree: PhDThe objectives of this study are to investigate and compare the dose distribution defined wi. N° de réf. du vendeur 5145353
Quantité disponible : Plus de 20 disponibles
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26356629675
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 355861364
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18356629665
Quantité disponible : 4 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Radiation Beam Collimation Used in Radiotherapy | Radiotherapy | Ehab Hegazy (u. a.) | Taschenbuch | Englisch | LAP Lambert Academic Publishing | EAN 9783659280498 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 106200290
Quantité disponible : 5 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The objectives of this study are to investigate and compare the dose distribution defined with divergent cerrobend alloy custom blocks to the distribution obtained with multileaf collimator (MLC) provided by high energy linear accelerator. The study was made for simple block replacement situations. Prior to making the comparison, multileaf collimator performance checks will be made. These checks include the following measurements: leaf Attenuation, leaf transmissions, in-between-leaf leakage properties and measurement of tongue and groove effect. By using of ionization chamber in water phantom, percent depth dose, beam flatness, symmetry, penumbra, leaf transmission and leakage will be measured. By using of radiographic films the transmission, penumbra, and verification of leaf position and leaf motion will be determined . Finally output factor of both multileaf collimator and cerrobend block will be measured same field sizes at the same conditions of dosimetry. The final aim of this study to improve the accuracy of cancer treatment delivery. N° de réf. du vendeur 9783659280498
Quantité disponible : 2 disponible(s)
Vendeur : Revaluation Books, Exeter, Royaume-Uni
Paperback. Etat : Brand New. 168 pages. 8.66x5.91x0.38 inches. In Stock. N° de réf. du vendeur 3659280496
Quantité disponible : 1 disponible(s)
Vendeur : Mispah books, Redhill, SURRE, Royaume-Uni
paperback. Etat : New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book. N° de réf. du vendeur ERICA82936592804966
Quantité disponible : 1 disponible(s)