The aim of this work was to perform quality control (QC) for six digital fluoroscopy units used for cardiovascular and interventional radiology procedures. Measurements were based on the QC protocol developed in the framework of European Commission (EU) DIMOND III project. Measurements made included: beam quality (half-value layer, HVL), peak tube voltage (kVp) accuracy, automatic exposure control(AEC) and patient dose in terms of entrance surface air kerma rate plus image intensifier input air kerma rate. Dose measurements were made using Calibrated dose rate meter. Field limitation and source to skin distant measurements in addition to evaluation radiation protection tools for occupation exposure were performed. Image quality was evaluated in terms of spatial resolution and Contrast detail detectability. Patient dose measurements was performed using polymethylmethacrylate (PMMA) patient equivalent phantom whereas image quality was assessed using Huettner Type 53 spatial frequency grating and TO10 contrast detail phantom.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
The aim of this work was to perform quality control (QC) for six digital fluoroscopy units used for cardiovascular and interventional radiology procedures. Measurements were based on the QC protocol developed in the framework of European Commission (EU) DIMOND III project. Measurements made included: beam quality (half-value layer, HVL), peak tube voltage (kVp) accuracy, automatic exposure control(AEC) and patient dose in terms of entrance surface air kerma rate plus image intensifier input air kerma rate. Dose measurements were made using Calibrated dose rate meter. Field limitation and source to skin distant measurements in addition to evaluation radiation protection tools for occupation exposure were performed. Image quality was evaluated in terms of spatial resolution and Contrast detail detectability. Patient dose measurements was performed using polymethylmethacrylate (PMMA) patient equivalent phantom whereas image quality was assessed using Huettner Type 53 spatial frequency grating and TO10 contrast detail phantom.
I am conducting my PhD in Medical Physics. I did my M.sc on Medical Physics from Sudan Academy of Sciences, 2010.B.Sc Physics from University of Khartoum, 2005.Researcher in diagnostic radiology at Sudan atomic energy commission(SAEC).
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The aim of this work was to perform quality control (QC) for six digital fluoroscopy units used for cardiovascular and interventional radiology procedures. Measurements were based on the QC protocol developed in the framework of European Commission (EU) DIMOND III project. Measurements made included: beam quality (half-value layer, HVL), peak tube voltage (kVp) accuracy, automatic exposure control(AEC) and patient dose in terms of entrance surface air kerma rate plus image intensifier input air kerma rate. Dose measurements were made using Calibrated dose rate meter. Field limitation and source to skin distant measurements in addition to evaluation radiation protection tools for occupation exposure were performed. Image quality was evaluated in terms of spatial resolution and Contrast detail detectability. Patient dose measurements was performed using polymethylmethacrylate (PMMA) patient equivalent phantom whereas image quality was assessed using Huettner Type 53 spatial frequency grating and TO10 contrast detail phantom. 84 pp. Englisch. N° de réf. du vendeur 9783659405846
Quantité disponible : 2 disponible(s)
Vendeur : Books Puddle, Woodside, NY, Etats-Unis
Etat : New. pp. 84. N° de réf. du vendeur 26128042198
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand pp. 84 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam. N° de réf. du vendeur 131496713
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND pp. 84. N° de réf. du vendeur 18128042204
Quantité disponible : 4 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The aim of this work was to perform quality control (QC) for six digital fluoroscopy units used for cardiovascular and interventional radiology procedures. Measurements were based on the QC protocol developed in the framework of European Commission (EU) DIMOND III project. Measurements made included: beam quality (half-value layer, HVL), peak tube voltage (kVp) accuracy, automatic exposure control(AEC) and patient dose in terms of entrance surface air kerma rate plus image intensifier input air kerma rate. Dose measurements were made using Calibrated dose rate meter. Field limitation and source to skin distant measurements in addition to evaluation radiation protection tools for occupation exposure were performed. Image quality was evaluated in terms of spatial resolution and Contrast detail detectability. Patient dose measurements was performed using polymethylmethacrylate (PMMA) patient equivalent phantom whereas image quality was assessed using Huettner Type 53 spatial frequency grating and TO10 contrast detail phantom. N° de réf. du vendeur 9783659405846
Quantité disponible : 1 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Nayl Edam Abdalrhman IbrahimI am conducting my PhD in Medical Physics. I did my M.sc on Medical Physics from Sudan Academy of Sciences, 2010.B.Sc Physics from University of Khartoum, 2005.Researcher in diagnostic radiology at Sudan . N° de réf. du vendeur 5154163
Quantité disponible : Plus de 20 disponibles
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -The aim of this work was to perform quality control (QC) for six digital fluoroscopy units used for cardiovascular and interventional radiology procedures. Measurements were based on the QC protocol developed in the framework of European Commission (EU) DIMOND III project. Measurements made included: beam quality (half-value layer, HVL), peak tube voltage (kVp) accuracy, automatic exposure control(AEC) and patient dose in terms of entrance surface air kerma rate plus image intensifier input air kerma rate. Dose measurements were made using Calibrated dose rate meter. Field limitation and source to skin distant measurements in addition to evaluation radiation protection tools for occupation exposure were performed. Image quality was evaluated in terms of spatial resolution and Contrast detail detectability. Patient dose measurements was performed using polymethylmethacrylate (PMMA) patient equivalent phantom whereas image quality was assessed using Huettner Type 53 spatial frequency grating and TO10 contrast detail phantom.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 84 pp. Englisch. N° de réf. du vendeur 9783659405846
Quantité disponible : 1 disponible(s)