Motor evoked potentials (MEP) elicited by transcranial magnetic stimulation (TMS) are used to asses corticospinal tract (CST) function in clinical practice. Advancements in technology have increased TMS precision yet clinical protocols do not reflect the gain in precision required for neuroscientific research. The aim of this study was to determine whether parameters extrapolated from MEP responses accurately reflect CST function. TMS was administered to healthy controls and acute subcortical stroke patients. A sigmoid-shaped dose-response curve was observed in control subjects and patients with lesions outside the CST. Relative amplitude of MEPs is the best descriptor of CST integrity. Absence of a sigmoid relationship indicates CST impairment.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Motor evoked potentials (MEP) elicited by transcranial magnetic stimulation (TMS) are used to asses corticospinal tract (CST) function in clinical practice. Advancements in technology have increased TMS precision yet clinical protocols do not reflect the gain in precision required for neuroscientific research. The aim of this study was to determine whether parameters extrapolated from MEP responses accurately reflect CST function. TMS was administered to healthy controls and acute subcortical stroke patients. A sigmoid-shaped dose-response curve was observed in control subjects and patients with lesions outside the CST. Relative amplitude of MEPs is the best descriptor of CST integrity. Absence of a sigmoid relationship indicates CST impairment.
Sasan completed his bachelor’s degree in the faculty of Health Sciences, school of Human Kinetics in 2007 at the University of Ottawa. He then completed his master’s degree in Neurological Sciences and Neurosurgery at McGill University. Since completing his master’s in 2009, he has been working as a professor at John Abbott College in Montreal.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Motor evoked potentials (MEP) elicited by transcranial magnetic stimulation (TMS) are used to asses corticospinal tract (CST) function in clinical practice. Advancements in technology have increased TMS precision yet clinical protocols do not reflect the gain in precision required for neuroscientific research. The aim of this study was to determine whether parameters extrapolated from MEP responses accurately reflect CST function. TMS was administered to healthy controls and acute subcortical stroke patients. A sigmoid-shaped dose-response curve was observed in control subjects and patients with lesions outside the CST. Relative amplitude of MEPs is the best descriptor of CST integrity. Absence of a sigmoid relationship indicates CST impairment. 92 pp. Englisch. N° de réf. du vendeur 9783659411649
Quantité disponible : 2 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Motor evoked potentials (MEP) elicited by transcranial magnetic stimulation (TMS) are used to asses corticospinal tract (CST) function in clinical practice. Advancements in technology have increased TMS precision yet clinical protocols do not reflect the gain in precision required for neuroscientific research. The aim of this study was to determine whether parameters extrapolated from MEP responses accurately reflect CST function. TMS was administered to healthy controls and acute subcortical stroke patients. A sigmoid-shaped dose-response curve was observed in control subjects and patients with lesions outside the CST. Relative amplitude of MEPs is the best descriptor of CST integrity. Absence of a sigmoid relationship indicates CST impairment. N° de réf. du vendeur 9783659411649
Quantité disponible : 1 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. N° de réf. du vendeur 5154567
Quantité disponible : Plus de 20 disponibles
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Motor evoked potentials (MEP) elicited by transcranial magnetic stimulation (TMS) are used to asses corticospinal tract (CST) function in clinical practice. Advancements in technology have increased TMS precision yet clinical protocols do not reflect the gain in precision required for neuroscientific research. The aim of this study was to determine whether parameters extrapolated from MEP responses accurately reflect CST function. TMS was administered to healthy controls and acute subcortical stroke patients. A sigmoid-shaped dose-response curve was observed in control subjects and patients with lesions outside the CST. Relative amplitude of MEPs is the best descriptor of CST integrity. Absence of a sigmoid relationship indicates CST impairment.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 92 pp. Englisch. N° de réf. du vendeur 9783659411649
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Stimulus-Response Curves: Descriptors of Corticospinal Tract Function | A functional imaging guided transcranial magnetic stimulation study in normal subjects and patients with subcortical stroke | Sasan Ghinani | Taschenbuch | 92 S. | Englisch | 2013 | LAP LAMBERT Academic Publishing | EAN 9783659411649 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 105722019
Quantité disponible : 5 disponible(s)