Enteric fever still remains a major endemic problem in India. Isolation of Genus Salmonella organisms from patient’s samples is the gold standard, however it is well recognized that facilities for culture are not readily available or limited in many areas. Although the culture method is gold standard, it is however time consuming, expensive and the culture positive cases are also very less hence serological testing for Salmonella antibodies is also essential. In this book to study the reliability of a single Widal test and to find out the diagnostic significance of anti O & anti H agglutinin titer in the diagnosis of typhoid fever have checked with sources believed to be reliable in their efforts to provide information that is completely and generally in accord with the standard. In the absence of vaccination and any bacterial infection an elevated levels of anti O and/or anti H agglutinin titer of <1:80 is the diagnostic value for typhoid fever. Our study showed that baseline titers of Salmonella antibodies should be determined in different areas as it can show geographical variation.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
(B.Sc. & M.Sc. Medical Microbiology)Tutor & Demonstrator,Department of Microbiology,Hind Institute of Medical Sciences,BBK, U.P., INDIA
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Enteric fever still remains a major endemic problem in India. Isolation of Genus Salmonella organisms from patient's samples is the gold standard, however it is well recognized that facilities for culture are not readily available or limited in many areas. Although the culture method is gold standard, it is however time consuming, expensive and the culture positive cases are also very less hence serological testing for Salmonella antibodies is also essential. In this book to study the reliability of a single Widal test and to find out the diagnostic significance of anti O & anti H agglutinin titer in the diagnosis of typhoid fever have checked with sources believed to be reliable in their efforts to provide information that is completely and generally in accord with the standard. In the absence of vaccination and any bacterial infection an elevated levels of anti O and/or anti H agglutinin titer of 1:80 is the diagnostic value for typhoid fever. Our study showed that baseline titers of Salmonella antibodies should be determined in different areas as it can show geographical variation. 76 pp. Englisch. N° de réf. du vendeur 9783659489808
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Singh Brij Nandan(B.Sc. & M.Sc. Medical Microbiology)Tutor & Demonstrator,Department of Microbiology,Hind Institute of Medical Sciences,BBK, U.P., INDIAEnteric fever still remains a major endemic problem in India. Isolation of Ge. N° de réf. du vendeur 5159481
Quantité disponible : Plus de 20 disponibles
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Enteric fever still remains a major endemic problem in India. Isolation of Genus Salmonella organisms from patient¿s samples is the gold standard, however it is well recognized that facilities for culture are not readily available or limited in many areas. Although the culture method is gold standard, it is however time consuming, expensive and the culture positive cases are also very less hence serological testing for Salmonella antibodies is also essential. In this book to study the reliability of a single Widal test and to find out the diagnostic significance of anti O & anti H agglutinin titer in the diagnosis of typhoid fever have checked with sources believed to be reliable in their efforts to provide information that is completely and generally in accord with the standard. In the absence of vaccination and any bacterial infection an elevated levels of anti O and/or anti H agglutinin titer ofVDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 76 pp. Englisch. N° de réf. du vendeur 9783659489808
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Enteric fever still remains a major endemic problem in India. Isolation of Genus Salmonella organisms from patient's samples is the gold standard, however it is well recognized that facilities for culture are not readily available or limited in many areas. Although the culture method is gold standard, it is however time consuming, expensive and the culture positive cases are also very less hence serological testing for Salmonella antibodies is also essential. In this book to study the reliability of a single Widal test and to find out the diagnostic significance of anti O & anti H agglutinin titer in the diagnosis of typhoid fever have checked with sources believed to be reliable in their efforts to provide information that is completely and generally in accord with the standard. In the absence of vaccination and any bacterial infection an elevated levels of anti O and/or anti H agglutinin titer of 1:80 is the diagnostic value for typhoid fever. Our study showed that baseline titers of Salmonella antibodies should be determined in different areas as it can show geographical variation. N° de réf. du vendeur 9783659489808
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Enteric Fever | Determination of Baseline Titres of Salmonella Antibody | Brij Nandan Singh (u. a.) | Taschenbuch | 76 S. | Englisch | 2013 | LAP LAMBERT Academic Publishing | EAN 9783659489808 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 105540381
Quantité disponible : 5 disponible(s)