The vertical position of elongated tokamak plasmas is unstable on the time scale of the eddy currents in the axisymmetric conducting structures. In the absence of feedback control, the plasma would drift vertically and quench on the wall, a situation known as Vertical Displacement Event (VDE), with serious consequences for machine integrity. As tokamaks approach reactor regimes, VDE’s cannot be tolerated: vertical feedback control must be robust against system uncertainty and the occurrence of noise and disturbances. At the same time, adaptive routines should be in place to handle unexpected events. The problem of robust control of the vertical position can be formulated in terms of identifying which variables affect vertical stability and which ones are not directly controlled/controllable; identifying the physical region of these variables, and the corresponding most unstable equilibria; and designing the control system to stabilize all equilibria with sufficient margin. The margin should be enough to allow the system to tolerate realistic scenarios of noise and disturbances.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The vertical position of elongated tokamak plasmas is unstable on the time scale of the eddy currents in the axisymmetric conducting structures. In the absence of feedback control, the plasma would drift vertically and quench on the wall, a situation known as Vertical Displacement Event (VDE), with serious consequences for machine integrity. As tokamaks approach reactor regimes, VDE's cannot be tolerated: vertical feedback control must be robust against system uncertainty and the occurrence of noise and disturbances. At the same time, adaptive routines should be in place to handle unexpected events. The problem of robust control of the vertical position can be formulated in terms of identifying which variables affect vertical stability and which ones are not directly controlled/controllable; identifying the physical region of these variables, and the corresponding most unstable equilibria; and designing the control system to stabilize all equilibria with sufficient margin. The margin should be enough to allow the system to tolerate realistic scenarios of noise and disturbances. 160 pp. Englisch. N° de réf. du vendeur 9783659532801
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. N° de réf. du vendeur 158960362
Quantité disponible : Plus de 20 disponibles
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. pp. 160. N° de réf. du vendeur 26128054804
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand pp. 160 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam. N° de réf. du vendeur 131484107
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND pp. 160. N° de réf. du vendeur 18128054814
Quantité disponible : 4 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -The vertical position of elongated tokamak plasmas is unstable on the time scale of the eddy currents in the axisymmetric conducting structures. In the absence of feedback control, the plasma would drift vertically and quench on the wall, a situation known as Vertical Displacement Event (VDE), with serious consequences for machine integrity. As tokamaks approach reactor regimes, VDE's cannot be tolerated: vertical feedback control must be robust against system uncertainty and the occurrence of noise and disturbances. At the same time, adaptive routines should be in place to handle unexpected events. The problem of robust control of the vertical position can be formulated in terms of identifying which variables affect vertical stability and which ones are not directly controlled/controllable; identifying the physical region of these variables, and the corresponding most unstable equilibria; and designing the control system to stabilize all equilibria with sufficient margin. The margin should be enough to allow the system to tolerate realistic scenarios of noise and disturbances.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 160 pp. Englisch. N° de réf. du vendeur 9783659532801
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The vertical position of elongated tokamak plasmas is unstable on the time scale of the eddy currents in the axisymmetric conducting structures. In the absence of feedback control, the plasma would drift vertically and quench on the wall, a situation known as Vertical Displacement Event (VDE), with serious consequences for machine integrity. As tokamaks approach reactor regimes, VDE's cannot be tolerated: vertical feedback control must be robust against system uncertainty and the occurrence of noise and disturbances. At the same time, adaptive routines should be in place to handle unexpected events. The problem of robust control of the vertical position can be formulated in terms of identifying which variables affect vertical stability and which ones are not directly controlled/controllable; identifying the physical region of these variables, and the corresponding most unstable equilibria; and designing the control system to stabilize all equilibria with sufficient margin. The margin should be enough to allow the system to tolerate realistic scenarios of noise and disturbances. N° de réf. du vendeur 9783659532801
Quantité disponible : 1 disponible(s)
Vendeur : Mispah books, Redhill, SURRE, Royaume-Uni
paperback. Etat : Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book. N° de réf. du vendeur ERICA82336595328006
Quantité disponible : 1 disponible(s)