Most of clinics around the world use an Intensity-modulated radiation therapy (IMRT) technique to treat cancer patients, although the clinical output must be accepted in all cases before treatment according to standards, there is range-wide spectrum of variations in the dosimetric results among them. The source of these discrepancies is the different factors affecting the quality of the IMRT plan during the optimization process and most of them are out of user control. Separated research efforts have discussed the different aspects of variation in order to find the most adequate conditions for IMRT plans. This work aims at studying two hundred and twelve Intensity-modulated radiation therapy (IMRT) plans and evaluating each of them under different conditions to study the effect of beam energy, number of beams, beams' orientations, and multileaf collimator (MLC) width on the plan quality.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Most of clinics around the world use an Intensity-modulated radiation therapy (IMRT) technique to treat cancer patients, although the clinical output must be accepted in all cases before treatment according to standards, there is range-wide spectrum of variations in the dosimetric results among them. The source of these discrepancies is the different factors affecting the quality of the IMRT plan during the optimization process and most of them are out of user control. Separated research efforts have discussed the different aspects of variation in order to find the most adequate conditions for IMRT plans. This work aims at studying two hundred and twelve Intensity-modulated radiation therapy (IMRT) plans and evaluating each of them under different conditions to study the effect of beam energy, number of beams, beams' orientations, and multileaf collimator (MLC) width on the plan quality. 88 pp. Englisch. N° de réf. du vendeur 9783659548048
Quantité disponible : 2 disponible(s)
Vendeur : Books Puddle, Woodside, NY, Etats-Unis
Etat : New. pp. 88. N° de réf. du vendeur 26128146937
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand pp. 88 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam. N° de réf. du vendeur 131392038
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND pp. 88. N° de réf. du vendeur 18128146931
Quantité disponible : 4 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Eldesoky IsmailIsmail Eldesoky worked as a medical physicist in Children s Cancer Hospital Cairo Egypt. Master s degree in 2011 .Ph.D. degree of medical physics in 2014 from Cairo University Giza EgyptMost of clinics aroun. N° de réf. du vendeur 5164000
Quantité disponible : Plus de 20 disponibles
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Most of clinics around the world use an Intensity-modulated radiation therapy (IMRT) technique to treat cancer patients, although the clinical output must be accepted in all cases before treatment according to standards, there is range-wide spectrum of variations in the dosimetric results among them. The source of these discrepancies is the different factors affecting the quality of the IMRT plan during the optimization process and most of them are out of user control. Separated research efforts have discussed the different aspects of variation in order to find the most adequate conditions for IMRT plans. This work aims at studying two hundred and twelve Intensity-modulated radiation therapy (IMRT) plans and evaluating each of them under different conditions to study the effect of beam energy, number of beams, beams' orientations, and multileaf collimator (MLC) width on the plan quality.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 88 pp. Englisch. N° de réf. du vendeur 9783659548048
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Most of clinics around the world use an Intensity-modulated radiation therapy (IMRT) technique to treat cancer patients, although the clinical output must be accepted in all cases before treatment according to standards, there is range-wide spectrum of variations in the dosimetric results among them. The source of these discrepancies is the different factors affecting the quality of the IMRT plan during the optimization process and most of them are out of user control. Separated research efforts have discussed the different aspects of variation in order to find the most adequate conditions for IMRT plans. This work aims at studying two hundred and twelve Intensity-modulated radiation therapy (IMRT) plans and evaluating each of them under different conditions to study the effect of beam energy, number of beams, beams' orientations, and multileaf collimator (MLC) width on the plan quality. N° de réf. du vendeur 9783659548048
Quantité disponible : 1 disponible(s)