Sterilization leads to the complete reduction of the pathogenic microorganisms from the surface of surgical gloves after they are manufactured. It is seen that many health hazardous microbes are present on the unsterilized gloves that leads urinary tract infections, skin infections, respiratory infections and food poisoning. These microbes includes gram positive Bacillus species mostly Bacillus subtilis, Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecalis and gram negative Klebsiella pneumoniae, E.coli etc. Sterilization of gloves was done with the help of boiling, autoclaving, dry heat and ethylene oxide but these were not much effective than that of sterilization with gamma radiation Co60. The aim of this work was the detection and the removal of microbial load from the surface of gloves that may cause hazardous effects to the human health. The gloves from 5 manufacturing companies were collected after the survey in order to test and detect the microbial load present on the gloves. After the microbial detection, the new samples of gloves were sent to PARAS for gamma radiation dose optimization. The gloves were treated at the 25, 30 and 35kGy.On 35kGy no load.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Sterilization leads to the complete reduction of the pathogenic microorganisms from the surface of surgical gloves after they are manufactured. It is seen that many health hazardous microbes are present on the unsterilized gloves that leads urinary tract infections, skin infections, respiratory infections and food poisoning. These microbes includes gram positive Bacillus species mostly Bacillus subtilis, Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecalis and gram negative Klebsiella pneumoniae, E.coli etc. Sterilization of gloves was done with the help of boiling, autoclaving, dry heat and ethylene oxide but these were not much effective than that of sterilization with gamma radiation Co60. The aim of this work was the detection and the removal of microbial load from the surface of gloves that may cause hazardous effects to the human health. The gloves from 5 manufacturing companies were collected after the survey in order to test and detect the microbial load present on the gloves. After the microbial detection, the new samples of gloves were sent to PARAS for gamma radiation dose optimization. The gloves were treated at the 25, 30 and 35kGy.On 35kGy no load. 92 pp. Englisch. N° de réf. du vendeur 9783659699511
Quantité disponible : 2 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Sterilization leads to the complete reduction of the pathogenic microorganisms from the surface of surgical gloves after they are manufactured. It is seen that many health hazardous microbes are present on the unsterilized gloves that leads urinary tract infections, skin infections, respiratory infections and food poisoning. These microbes includes gram positive Bacillus species mostly Bacillus subtilis, Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecalis and gram negative Klebsiella pneumoniae, E.coli etc. Sterilization of gloves was done with the help of boiling, autoclaving, dry heat and ethylene oxide but these were not much effective than that of sterilization with gamma radiation Co60. The aim of this work was the detection and the removal of microbial load from the surface of gloves that may cause hazardous effects to the human health. The gloves from 5 manufacturing companies were collected after the survey in order to test and detect the microbial load present on the gloves. After the microbial detection, the new samples of gloves were sent to PARAS for gamma radiation dose optimization. The gloves were treated at the 25, 30 and 35kGy.On 35kGy no load. N° de réf. du vendeur 9783659699511
Quantité disponible : 1 disponible(s)
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26405909194
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 407245077
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18405909184
Quantité disponible : 4 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Sterilization leads to the complete reduction of the pathogenic microorganisms from the surface of surgical gloves after they are manufactured. It is seen that many health hazardous microbes are present on the unsterilized gloves that leads urinary tract infections, skin infections, respiratory infections and food poisoning. These microbes includes gram positive Bacillus species mostly Bacillus subtilis, Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecalis and gram negative Klebsiella pneumoniae, E.coli etc. Sterilization of gloves was done with the help of boiling, autoclaving, dry heat and ethylene oxide but these were not much effective than that of sterilization with gamma radiation Co60. The aim of this work was the detection and the removal of microbial load from the surface of gloves that may cause hazardous effects to the human health. The gloves from 5 manufacturing companies were collected after the survey in order to test and detect the microbial load present on the gloves. After the microbial detection, the new samples of gloves were sent to PARAS for gamma radiation dose optimization. The gloves were treated at the 25, 30 and 35kGy.On 35kGy no load.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 92 pp. Englisch. N° de réf. du vendeur 9783659699511
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Gamma Radiation Dose Optimization for Surgical Gloves | Reducing Microbial load by optimizing the gamma radiation dose | Beenish Hassan (u. a.) | Taschenbuch | 92 S. | Englisch | 2015 | LAP LAMBERT Academic Publishing | EAN 9783659699511 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 104674248
Quantité disponible : 5 disponible(s)