The transient response of the voltage on the secondary is investigated with following changes in the model. Two instants of switching are considered. Instrument transformers are the integral components of power systems .Capacitive Voltage Transformers (CVTs) are widely used for protection, metering and control applications. The work presents the modeling of CVT by its equivalent circuit. A 420kV CVT is considered with a line to ground fault on the primary side. Another kind of transient response called ferro resonance is also studied. Three types of ferro resonance suppression circuits (FSCs) are considered to dampen the behavior due to ferro resonance The parameters of these FSCs are discussed. The impedance, power characteristics of these FSCs with variation of frequency are studied. Furthermore, using metal oxide varistors are used to improve the performance of the FSCs.The two switching instants in presence of FSC are also evaluated .The effect of FSCs on the transient response of CVTs are presented in this work. The effect of magnetizing current of intermediate voltage transformer on the transient response is also simulated.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
The transient response of the voltage on the secondary is investigated with following changes in the model. Two instants of switching are considered. Instrument transformers are the integral components of power systems .Capacitive Voltage Transformers (CVTs) are widely used for protection, metering and control applications. The work presents the modeling of CVT by its equivalent circuit. A 420kV CVT is considered with a line to ground fault on the primary side. Another kind of transient response called ferro resonance is also studied. Three types of ferro resonance suppression circuits (FSCs) are considered to dampen the behavior due to ferro resonance The parameters of these FSCs are discussed. The impedance, power characteristics of these FSCs with variation of frequency are studied. Furthermore, using metal oxide varistors are used to improve the performance of the FSCs.The two switching instants in presence of FSC are also evaluated .The effect of FSCs on the transient response of CVTs are presented in this work. The effect of magnetizing current of intermediate voltage transformer on the transient response is also simulated.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The transient response of the voltage on the secondary is investigated with following changes in the model. Two instants of switching are considered. Instrument transformers are the integral components of power systems .Capacitive Voltage Transformers (CVTs) are widely used for protection, metering and control applications. The work presents the modeling of CVT by its equivalent circuit. A 420kV CVT is considered with a line to ground fault on the primary side. Another kind of transient response called ferro resonance is also studied. Three types of ferro resonance suppression circuits (FSCs) are considered to dampen the behavior due to ferro resonance The parameters of these FSCs are discussed. The impedance, power characteristics of these FSCs with variation of frequency are studied. Furthermore, using metal oxide varistors are used to improve the performance of the FSCs.The two switching instants in presence of FSC are also evaluated .The effect of FSCs on the transient response of CVTs are presented in this work. The effect of magnetizing current of intermediate voltage transformer on the transient response is also simulated. 68 pp. Englisch. N° de réf. du vendeur 9783659743627
Quantité disponible : 2 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The transient response of the voltage on the secondary is investigated with following changes in the model. Two instants of switching are considered. Instrument transformers are the integral components of power systems .Capacitive Voltage Transformers (CVTs) are widely used for protection, metering and control applications. The work presents the modeling of CVT by its equivalent circuit. A 420kV CVT is considered with a line to ground fault on the primary side. Another kind of transient response called ferro resonance is also studied. Three types of ferro resonance suppression circuits (FSCs) are considered to dampen the behavior due to ferro resonance The parameters of these FSCs are discussed. The impedance, power characteristics of these FSCs with variation of frequency are studied. Furthermore, using metal oxide varistors are used to improve the performance of the FSCs.The two switching instants in presence of FSC are also evaluated .The effect of FSCs on the transient response of CVTs are presented in this work. The effect of magnetizing current of intermediate voltage transformer on the transient response is also simulated. N° de réf. du vendeur 9783659743627
Quantité disponible : 1 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Annabattula JawaharJawahar A has obtained his B.Tech. in Electrical and Electronics Engineering from Jawaharlal Nehru Technological University Kakinada, Andhra Pradesh in 2012. He obtained M.Tech. in Power System Control and Automati. N° de réf. du vendeur 158876174
Quantité disponible : Plus de 20 disponibles
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -The transient response of the voltage on the secondary is investigated with following changes in the model. Two instants of switching are considered. Instrument transformers are the integral components of power systems .Capacitive Voltage Transformers (CVTs) are widely used for protection, metering and control applications. The work presents the modeling of CVT by its equivalent circuit. A 420kV CVT is considered with a line to ground fault on the primary side. Another kind of transient response called ferro resonance is also studied. Three types of ferro resonance suppression circuits (FSCs) are considered to dampen the behavior due to ferro resonance The parameters of these FSCs are discussed. The impedance, power characteristics of these FSCs with variation of frequency are studied. Furthermore, using metal oxide varistors are used to improve the performance of the FSCs.The two switching instants in presence of FSC are also evaluated .The effect of FSCs on the transient response of CVTs are presented in this work. The effect of magnetizing current of intermediate voltage transformer on the transient response is also simulated.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 68 pp. Englisch. N° de réf. du vendeur 9783659743627
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Transient Performance of Capacitive Voltage Transformers | Jawahar Annabattula (u. a.) | Taschenbuch | 68 S. | Englisch | 2015 | LAP LAMBERT Academic Publishing | EAN 9783659743627 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 104485099
Quantité disponible : 5 disponible(s)