The components of the station were studied, the data regarding breakdowns was collected. Operation reports, and times of stopping were taken during the year (2017-2021). The problems that cause the breakdowns are classified into internal and external problems and are tabled and converted into diagrams. From the analysis, it was found that the internal problems represents (73.7%) of the total problems. (58.1%) of the internal problems is found in fueling system, cooling systems, besides other main problems that range between weakness of preventive maintenance, operational errors and inappropriate work environment. The study recommends to tackle the problems through the following procedures:- Using clean tanker provided with pumping machine for fueling and pumping fuels instead of the recent used method.- The necessity to conduct continuous physical test when the station is in service and upon stoppage as well. - The necessity to use coolant water and lubricant oil that are recommended by the manufacturer.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : PBShop.store US, Wood Dale, IL, Etats-Unis
PAP. Etat : New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. N° de réf. du vendeur L0-9783659758607
Quantité disponible : Plus de 20 disponibles
Vendeur : PBShop.store UK, Fairford, GLOS, Royaume-Uni
PAP. Etat : New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. N° de réf. du vendeur L0-9783659758607
Quantité disponible : Plus de 20 disponibles
Vendeur : Ria Christie Collections, Uxbridge, Royaume-Uni
Etat : New. In. N° de réf. du vendeur ria9783659758607_new
Quantité disponible : Plus de 20 disponibles
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The components of the station were studied, the data regarding breakdowns was collected. Operation reports, and times of stopping were taken during the year (2017-2021). The problems that cause the breakdowns are classified into internal and external problems and are tabled and converted into diagrams. From the analysis, it was found that the internal problems represents (73.7%) of the total problems. (58.1%) of the internal problems is found in fueling system, cooling systems, besides other main problems that range between weakness of preventive maintenance, operational errors and inappropriate work environment. The study recommends to tackle the problems through the following procedures:- Using clean tanker provided with pumping machine for fueling and pumping fuels instead of the recent used method.- The necessity to conduct continuous physical test when the station is in service and upon stoppage as well. - The necessity to use coolant water and lubricant oil that are recommended by the manufacturer. 88 pp. Englisch. N° de réf. du vendeur 9783659758607
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: OHAJ MOHAMED ARTEGADr. Osama Mohammed Elmardi Suleiman Khayal was born in Atbara, Sudan in 1966. He received a bachelor degree in mechanical engineering from Sudan University of science and technology in 1998, and a master degree in. N° de réf. du vendeur 1959525695
Quantité disponible : Plus de 20 disponibles
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -The components of the station were studied, the data regarding breakdowns was collected. Operation reports, and times of stopping were taken during the year (2017-2021). The problems that cause the breakdowns are classified into internal and external problems and are tabled and converted into diagrams. From the analysis, it was found that the internal problems represents (73.7%) of the total problems. (58.1%) of the internal problems is found in fueling system, cooling systems, besides other main problems that range between weakness of preventive maintenance, operational errors and inappropriate work environment. The study recommends to tackle the problems through the following procedures:- Using clean tanker provided with pumping machine for fueling and pumping fuels instead of the recent used method.- The necessity to conduct continuous physical test when the station is in service and upon stoppage as well. - The necessity to use coolant water and lubricant oil that are recommended by the manufacturer.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 88 pp. Englisch. N° de réf. du vendeur 9783659758607
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The components of the station were studied, the data regarding breakdowns was collected. Operation reports, and times of stopping were taken during the year (2017-2021). The problems that cause the breakdowns are classified into internal and external problems and are tabled and converted into diagrams. From the analysis, it was found that the internal problems represents (73.7%) of the total problems. (58.1%) of the internal problems is found in fueling system, cooling systems, besides other main problems that range between weakness of preventive maintenance, operational errors and inappropriate work environment. The study recommends to tackle the problems through the following procedures:- Using clean tanker provided with pumping machine for fueling and pumping fuels instead of the recent used method.- The necessity to conduct continuous physical test when the station is in service and upon stoppage as well. - The necessity to use coolant water and lubricant oil that are recommended by the manufacturer. N° de réf. du vendeur 9783659758607
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Electricity Shortage in Suakin | Case Study in Suakin Locality - Sudan | Mohamed Artega Ohaj (u. a.) | Taschenbuch | Einband - flex.(Paperback) | Englisch | 2024 | LAP LAMBERT Academic Publishing | EAN 9783659758607 | Verantwortliche Person für die EU: OmniScriptum GmbH & Co. KG, Bahnhofstr. 28, 66111 Saarbrücken, info[at]akademikerverlag[dot]de | Anbieter: preigu. N° de réf. du vendeur 130397850
Quantité disponible : 5 disponible(s)