Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Failure mechanisms, such as implant-induced adverse bone remodelling, excessive implant-bone interface stresses and lack of primary stability, are known to affect the outcome of cementless Total Hip Arthroplasty (THA). These failure mechanisms are reported to be influenced by the design of femoral implant. Employing shape optimization as pre-clinical design tool, stem geometries can be evaluated based on these failure objectives. However, these objectives may sometimes be mutually conflicting. Hence, it is necessary to implement multi-objective shape optimization to tackle the design conflict. Using a patient-specific femur and an initial design of TriLock® (DePuy) stem, a fully-automated 3-D shape optimization scheme was developed based on minimization of bone remodelling and interface stresses. Further compromised designs of femoral implants were sought in study by introducing a novel hybrid framework for simultaneous minimization of all three objectives. The study favoured lateral-flared designs having rectangular proximal transverse sections and greater stem-sizes for improved stability. Final trade-off stem geometries predicted favourable load transfer and improved fixation. 172 pp. Englisch. N° de réf. du vendeur 9783659937330
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Chanda SouptickDr. Souptick Chanda was born on 28 January 1981 in India. After completing his Masters in Mechanical Engineering, he worked for two prominent corporate sectors. He did his PhD from IIT Kharagpur in 2015. After a short . N° de réf. du vendeur 510204613
Quantité disponible : Plus de 20 disponibles
Vendeur : Books Puddle, Woodside, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26396997974
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 400427657
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18396997980
Quantité disponible : 4 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Shape Optimization of Femoral Implant in Total Hip Arthroplasty | A Finite Element Approach Using Combined Neural Network and Genetic Algorithms | Souptick Chanda | Taschenbuch | Englisch | 2017 | LAP LAMBERT Academic Publishing | EAN 9783659937330 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu Print on Demand. N° de réf. du vendeur 120576214
Quantité disponible : 5 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Failure mechanisms, such as implant-induced adverse bone remodelling, excessive implant-bone interface stresses and lack of primary stability, are known to affect the outcome of cementless Total Hip Arthroplasty (THA). These failure mechanisms are reported to be influenced by the design of femoral implant. Employing shape optimization as pre-clinical design tool, stem geometries can be evaluated based on these failure objectives. However, these objectives may sometimes be mutually conflicting. Hence, it is necessary to implement multi-objective shape optimization to tackle the design conflict. Using a patient-specific femur and an initial design of TriLock® (DePuy) stem, a fully-automated 3-D shape optimization scheme was developed based on minimization of bone remodelling and interface stresses. Further compromised designs of femoral implants were sought in study by introducing a novel hybrid framework for simultaneous minimization of all three objectives. The study favoured lateral-flared designs having rectangular proximal transverse sections and greater stem-sizes for improved stability. Final trade-off stem geometries predicted favourable load transfer and improved fixation.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 172 pp. Englisch. N° de réf. du vendeur 9783659937330
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Failure mechanisms, such as implant-induced adverse bone remodelling, excessive implant-bone interface stresses and lack of primary stability, are known to affect the outcome of cementless Total Hip Arthroplasty (THA). These failure mechanisms are reported to be influenced by the design of femoral implant. Employing shape optimization as pre-clinical design tool, stem geometries can be evaluated based on these failure objectives. However, these objectives may sometimes be mutually conflicting. Hence, it is necessary to implement multi-objective shape optimization to tackle the design conflict. Using a patient-specific femur and an initial design of TriLock® (DePuy) stem, a fully-automated 3-D shape optimization scheme was developed based on minimization of bone remodelling and interface stresses. Further compromised designs of femoral implants were sought in study by introducing a novel hybrid framework for simultaneous minimization of all three objectives. The study favoured lateral-flared designs having rectangular proximal transverse sections and greater stem-sizes for improved stability. Final trade-off stem geometries predicted favourable load transfer and improved fixation. N° de réf. du vendeur 9783659937330
Quantité disponible : 1 disponible(s)