Vendeur : medimops, Berlin, Allemagne
Etat : very good. Gut/Very good: Buch bzw. Schutzumschlag mit wenigen Gebrauchsspuren an Einband, Schutzumschlag oder Seiten. / Describes a book or dust jacket that does show some signs of wear on either the binding, dust jacket or pages. N° de réf. du vendeur M03736990103-V
Quantité disponible : 1 disponible(s)
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The knowledge of behavior of liquids with free surfaces to their surrounding gaseous phase in compensated gravity is essential to the development of tank systems for spacecrafts. In microgravity, the liquid behavior is dominated by capillary forces, which are used to position and redistribute liquid propellant in a desired way for the mission. The body forces occurring due to residual accelerations, which can be caused by spin during the ballistic flight phases, force the liquid to reorient towards a new equilibrium state of the free surface. Due to spin the liquid is driven away from the tank outlet and located along tank walls in partially filled tanks. To assure enough liquid fuel over the tank outlet, so-called Propellant Management Devices (PMD¿s), are employed. A PMD is a static, usually metal structure, which either provides a passage way for a liquid in microgravity or stores a certain amount of liquid at a desired location. Some PMD¿s are designed to be refillable in periods of microgravity due to openings in the outer housing or by a housing composed of perforated metallic sheets. These reservoirs are refilled in periods of compensated gravity in order to provide the required amount of liquid fuel for attitude control or other maneuverings. Relatively large disturbances, such as lateral accelerations and spin, can drive the liquid fuel out of the reservoir, resulting in malfunction of the device. During spilling, gas enters the device such that only a residual amount of liquid propellant can be kept in the reservoir. Moreover, the connection to the bulk liquid in the tank may be interrupted such that refilling of the reservoir is disrupted. Hence, a PMD with two parallel disks forming the inlet and a venting tube at the topmost point of the outer housing shall be designed such that its refillable structure is only filled with liquid without any gas or vapor being easily trapped during operations. 286 pp. Englisch. N° de réf. du vendeur 9783736990104
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. KlappentextrnrnThe knowledge of behavior of liquids with free surfaces to their surrounding gaseous phase in compensated gravity is essential to the development of tank systems for spacecrafts. In microgravity, the liquid behavior is dominated b. N° de réf. du vendeur 82442999
Quantité disponible : Plus de 20 disponibles
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -The knowledge of behavior of liquids with free surfaces to their surrounding gaseous phase in compensated gravity is essential to the development of tank systems for spacecrafts. In microgravity, the liquid behavior is dominated by capillary forces, which are used to position and redistribute liquid propellant in a desired way for the mission. The body forces occurring due to residual accelerations, which can be caused by spin during the ballistic flight phases, force the liquid to reorient towards a new equilibrium state of the free surface. Due to spin the liquid is driven away from the tank outlet and located along tank walls in partially filled tanks. To assure enough liquid fuel over the tank outlet, so-called Propellant Management Devices (PMD's), are employed. A PMD is a static, usually metal structure, which either provides a passage way for a liquid in microgravity or stores a certain amount of liquid at a desired location. Some PMD's are designed to be refillable in periods of microgravity due to openings in the outer housing or by a housing composed of perforated metallic sheets. These reservoirs are refilled in periods of compensated gravity in order to provide the required amount of liquid fuel for attitude control or other maneuverings. Relatively large disturbances, such as lateral accelerations and spin, can drive the liquid fuel out of the reservoir, resulting in malfunction of the device. During spilling, gas enters the device such that only a residual amount of liquid propellant can be kept in the reservoir. Moreover, the connection to the bulk liquid in the tank may be interrupted such that refilling of the reservoir is disrupted. Hence, a PMD with two parallel disks forming the inlet and a venting tube at the topmost point of the outer housing shall be designed such that its refillable structure is only filled with liquid without any gas or vapor being easily trapped during operations.Cuvillier Verlag, Nonnenstieg 8, 37075 Göttingen 286 pp. Englisch. N° de réf. du vendeur 9783736990104
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The knowledge of behavior of liquids with free surfaces to their surrounding gaseous phase in compensated gravity is essential to the development of tank systems for spacecrafts. In microgravity, the liquid behavior is dominated by capillary forces, which are used to position and redistribute liquid propellant in a desired way for the mission. The body forces occurring due to residual accelerations, which can be caused by spin during the ballistic flight phases, force the liquid to reorient towards a new equilibrium state of the free surface. Due to spin the liquid is driven away from the tank outlet and located along tank walls in partially filled tanks. To assure enough liquid fuel over the tank outlet, so-called Propellant Management Devices (PMD¿s), are employed. A PMD is a static, usually metal structure, which either provides a passage way for a liquid in microgravity or stores a certain amount of liquid at a desired location. Some PMD¿s are designed to be refillable in periods of microgravity due to openings in the outer housing or by a housing composed of perforated metallic sheets. These reservoirs are refilled in periods of compensated gravity in order to provide the required amount of liquid fuel for attitude control or other maneuverings. Relatively large disturbances, such as lateral accelerations and spin, can drive the liquid fuel out of the reservoir, resulting in malfunction of the device. During spilling, gas enters the device such that only a residual amount of liquid propellant can be kept in the reservoir. Moreover, the connection to the bulk liquid in the tank may be interrupted such that refilling of the reservoir is disrupted. Hence, a PMD with two parallel disks forming the inlet and a venting tube at the topmost point of the outer housing shall be designed such that its refillable structure is only filled with liquid without any gas or vapor being easily trapped during operations. N° de réf. du vendeur 9783736990104
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Meniscus Stability in Rotating Systems | Yvonne Chen | Taschenbuch | 286 S. | Englisch | 2015 | Cuvillier | EAN 9783736990104 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu Print on Demand. N° de réf. du vendeur 104317865
Quantité disponible : 5 disponible(s)