As acute breathlessness has been recognized as an important medical problem, multiple attempts has been made to improve the management of such a condition. Several researches have been done to show the correlation between ETCO2 and PaCO2 especially in intubated patients. For more than 40 years since it was first used, several attempts has been made to recognize the utility and accuracy of capnometry use in patients with respiratory conditions. Microstream capnometer has a potential to predict PaCO2 level especially in the case of pure acidosis and hypocapnia. It can be a potential form of non invasive cardiopulmonary monitoring in non-intubated acute breathlessness patient. However the use of ETCO2 to predict PaCO2 should be done with caution especially in cases that involve pulmonary disorders and acid base imbalance.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -As acute breathlessness has been recognized as an important medical problem, multiple attempts has been made to improve the management of such a condition. Several researches have been done to show the correlation between ETCO2 and PaCO2 especially in intubated patients. For more than 40 years since it was first used, several attempts has been made to recognize the utility and accuracy of capnometry use in patients with respiratory conditions. Microstream capnometer has a potential to predict PaCO2 level especially in the case of pure acidosis and hypocapnia. It can be a potential form of non invasive cardiopulmonary monitoring in non-intubated acute breathlessness patient. However the use of ETCO2 to predict PaCO2 should be done with caution especially in cases that involve pulmonary disorders and acid base imbalance. 120 pp. Englisch. N° de réf. du vendeur 9783838383668
Quantité disponible : 2 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - As acute breathlessness has been recognized as an important medical problem, multiple attempts has been made to improve the management of such a condition. Several researches have been done to show the correlation between ETCO2 and PaCO2 especially in intubated patients. For more than 40 years since it was first used, several attempts has been made to recognize the utility and accuracy of capnometry use in patients with respiratory conditions. Microstream capnometer has a potential to predict PaCO2 level especially in the case of pure acidosis and hypocapnia. It can be a potential form of non invasive cardiopulmonary monitoring in non-intubated acute breathlessness patient. However the use of ETCO2 to predict PaCO2 should be done with caution especially in cases that involve pulmonary disorders and acid base imbalance. N° de réf. du vendeur 9783838383668
Quantité disponible : 1 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Nik Ab Rahman Nik HisamuddinAssociate Professor Dr Nik Hisamuddin Nik Ab Rahman, MBChB, MMed, ACEP. Obtained his basic medical degree from the University of Glasgow. Current position include the head and consultant Emergency Medic. N° de réf. du vendeur 5418624
Quantité disponible : Plus de 20 disponibles
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -As acute breathlessness has been recognized as an important medical problem, multiple attempts has been made to improve the management of such a condition. Several researches have been done to show the correlation between ETCO2 and PaCO2 especially in intubated patients. For more than 40 years since it was first used, several attempts has been made to recognize the utility and accuracy of capnometry use in patients with respiratory conditions. Microstream capnometer has a potential to predict PaCO2 level especially in the case of pure acidosis and hypocapnia. It can be a potential form of non invasive cardiopulmonary monitoring in non-intubated acute breathlessness patient. However the use of ETCO2 to predict PaCO2 should be done with caution especially in cases that involve pulmonary disorders and acid base imbalance.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 120 pp. Englisch. N° de réf. du vendeur 9783838383668
Quantité disponible : 1 disponible(s)