A new, simple, rapid, selective, precise and accurate isocratic RP-HPLC assay has been developed for simultaneous estimation of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole and Ornidazole in tablet formulations. The separation was achieved by using C-18 column (Phenomenax, 250 x 4.6mm i.d.) coupled with a guard column of same material, in mobile phase Acetonitrile: Water: Tri ethylamine (25:75). The pH of mobile phase was adjusted to 6.0 ± 0.1 with 50% ortho phosphoric acid. The flow rate was 1.0 mL.min-1 and the separated drugs were detected using UV detector at the wavelength of 300 nm. The retention time of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole, and Ornidazole was noted to be 2.7, 3.5, 4.5 and 5.8 min, respectively, indicative of rather shorter analysis time. The method was validated as per ICH guidelines. The proposed method was found to be accurate, reproducible, and consistent. It was successfully applied for the analysis of these drugs in marketed formulations and could be effectively used for the routine analysis of formulations containing any one of the above drugs, or a combination, without any alteration in the chromatographic conditions.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
A new, simple, rapid, selective, precise and accurate isocratic RP-HPLC assay has been developed for simultaneous estimation of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole and Ornidazole in tablet formulations. The separation was achieved by using C-18 column (Phenomenax, 250 x 4.6mm i.d.) coupled with a guard column of same material, in mobile phase Acetonitrile: Water: Tri ethylamine (25:75). The pH of mobile phase was adjusted to 6.0 ± 0.1 with 50% ortho phosphoric acid. The flow rate was 1.0 mL.min-1 and the separated drugs were detected using UV detector at the wavelength of 300 nm. The retention time of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole, and Ornidazole was noted to be 2.7, 3.5, 4.5 and 5.8 min, respectively, indicative of rather shorter analysis time. The method was validated as per ICH guidelines. The proposed method was found to be accurate, reproducible, and consistent. It was successfully applied for the analysis of these drugs in marketed formulations and could be effectively used for the routine analysis of formulations containing any one of the above drugs, or a combination, without any alteration in the chromatographic conditions.
Mukesh Maithani did his Master of Pharmacy in 2007 from NIEC (UP Technical University) Lucknow. He is working as Assistant Professor in Shobhit University, Meerut and also pursuing PhD in Pharmaceutical Sciences from the same. He has published number of research and review articles in Journals national and international of repute.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -A new, simple, rapid, selective, precise and accurate isocratic RP-HPLC assay has been developed for simultaneous estimation of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole and Ornidazole in tablet formulations. The separation was achieved by using C-18 column (Phenomenax, 250 x 4.6mm i.d.) coupled with a guard column of same material, in mobile phase Acetonitrile: Water: Tri ethylamine (25:75). The pH of mobile phase was adjusted to 6.0 ± 0.1 with 50% ortho phosphoric acid. The flow rate was 1.0 mL.min-1 and the separated drugs were detected using UV detector at the wavelength of 300 nm. The retention time of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole, and Ornidazole was noted to be 2.7, 3.5, 4.5 and 5.8 min, respectively, indicative of rather shorter analysis time. The method was validated as per ICH guidelines. The proposed method was found to be accurate, reproducible, and consistent. It was successfully applied for the analysis of these drugs in marketed formulations and could be effectively used for the routine analysis of formulations containing any one of the above drugs, or a combination, without any alteration in the chromatographic conditions. 140 pp. Englisch. N° de réf. du vendeur 9783843375153
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Maithani MukeshMukesh Maithani did his Master of Pharmacy in 2007 from NIEC (UP Technical University) Lucknow. He is working as Assistant Professor in Shobhit University, Meerut and also pursuing PhD in Pharmaceutical Sciences from t. N° de réf. du vendeur 5467400
Quantité disponible : Plus de 20 disponibles
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A new, simple, rapid, selective, precise and accurate isocratic RP-HPLC assay has been developed for simultaneous estimation of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole and Ornidazole in tablet formulations. The separation was achieved by using C-18 column (Phenomenax, 250 x 4.6mm i.d.) coupled with a guard column of same material, in mobile phase Acetonitrile: Water: Tri ethylamine (25:75). The pH of mobile phase was adjusted to 6.0 ± 0.1 with 50% ortho phosphoric acid. The flow rate was 1.0 mL.min-1 and the separated drugs were detected using UV detector at the wavelength of 300 nm. The retention time of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole, and Ornidazole was noted to be 2.7, 3.5, 4.5 and 5.8 min, respectively, indicative of rather shorter analysis time. The method was validated as per ICH guidelines. The proposed method was found to be accurate, reproducible, and consistent. It was successfully applied for the analysis of these drugs in marketed formulations and could be effectively used for the routine analysis of formulations containing any one of the above drugs, or a combination, without any alteration in the chromatographic conditions. N° de réf. du vendeur 9783843375153
Quantité disponible : 1 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -A new, simple, rapid, selective, precise and accurate isocratic RP-HPLC assay has been developed for simultaneous estimation of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole and Ornidazole in tablet formulations. The separation was achieved by using C-18 column (Phenomenax, 250 x 4.6mm i.d.) coupled with a guard column of same material, in mobile phase Acetonitrile: Water: Tri ethylamine (25:75). The pH of mobile phase was adjusted to 6.0 ± 0.1 with 50% ortho phosphoric acid. The flow rate was 1.0 mL.min-1 and the separated drugs were detected using UV detector at the wavelength of 300 nm. The retention time of Ciprofloxacin Hydrochloride, Ofloxacin, Tinidazole, and Ornidazole was noted to be 2.7, 3.5, 4.5 and 5.8 min, respectively, indicative of rather shorter analysis time. The method was validated as per ICH guidelines. The proposed method was found to be accurate, reproducible, and consistent. It was successfully applied for the analysis of these drugs in marketed formulations and could be effectively used for the routine analysis of formulations containing any one of the above drugs, or a combination, without any alteration in the chromatographic conditions.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 140 pp. Englisch. N° de réf. du vendeur 9783843375153
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Simultaneous Estimation of Drugs by RP-HPLC | SIMULTANEOUS ESTIMATION OF [.], OFLOXACIN, TINIDAZOLE AND ORNIDAZOLE BY REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY | Mukesh Maithani | Taschenbuch | 140 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783843375153 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu. N° de réf. du vendeur 107133450
Quantité disponible : 5 disponible(s)
Vendeur : Mispah books, Redhill, SURRE, Royaume-Uni
Paperback. Etat : Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book. N° de réf. du vendeur ERICA79638433751516
Quantité disponible : 1 disponible(s)