Proper distribution of conditioned air in an air conditioning room is very important for comfort air conditioning to maintain the comfort parameters within a prescribed limit. Supply air outlets and return air locations affects the human comfort significantly by maintaining comfort parameters uniformly. Thus, the problem of finding the optimal arrangements of location of the supply air diffusers and return air outlets has been considered in this book. CFD through FLUENT is considered for analysis of the problem. Different arrangements of supply and return air points are considered for observing the comfort parameters like air temperature, air velocity, relative humidity in room air distribution so that the optimal arrangements can be evaluated where majority of the occupants present in the room feel comfortable. An experimental validation of the work is also performed to check the applicability of CFD in the analysis of room air distribution. This book will be helpful for the researchers using CFD as a tool for analysis of room air distribution with prototype experimentation validation so that the procedure can be applied to real life requirements.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Nitul Kalita an M.Tech.in Thermal Engineering from National Institute of Technology (NIT), Silchar, Assam is presently working as Senior Engineer (Mechanical) in Brahmaputra Cracker and Polymer Limited, Dibrugarh, Assam. Dr. Rahul Dev Misra, Ph.D. from IIT Roorkee is currently a Professor in Mechanical Engineering Department at NIT, Silchar.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : PBShop.store US, Wood Dale, IL, Etats-Unis
PAP. Etat : New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. N° de réf. du vendeur L0-9783844383966
Quantité disponible : Plus de 20 disponibles
Vendeur : PBShop.store UK, Fairford, GLOS, Royaume-Uni
PAP. Etat : New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. N° de réf. du vendeur L0-9783844383966
Quantité disponible : Plus de 20 disponibles
Vendeur : Ria Christie Collections, Uxbridge, Royaume-Uni
Etat : New. In. N° de réf. du vendeur ria9783844383966_new
Quantité disponible : Plus de 20 disponibles
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Proper distribution of conditioned air in an air conditioning room is very important for comfort air conditioning to maintain the comfort parameters within a prescribed limit. Supply air outlets and return air locations affects the human comfort significantly by maintaining comfort parameters uniformly. Thus, the problem of finding the optimal arrangements of location of the supply air diffusers and return air outlets has been considered in this book. CFD through FLUENT is considered for analysis of the problem. Different arrangements of supply and return air points are considered for observing the comfort parameters like air temperature, air velocity, relative humidity in room air distribution so that the optimal arrangements can be evaluated where majority of the occupants present in the room feel comfortable. An experimental validation of the work is also performed to check the applicability of CFD in the analysis of room air distribution. This book will be helpful for the researchers using CFD as a tool for analysis of room air distribution with prototype experimentation validation so that the procedure can be applied to real life requirements. 148 pp. Englisch. N° de réf. du vendeur 9783844383966
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Kalita NitulNitul Kalita an M.Tech.in Thermal Engineering from National Institute of Technology (NIT), Silchar, Assam is presently working as Senior Engineer (Mechanical) in Brahmaputra Cracker and Polymer Limited, Dibrugarh, Assam. . N° de réf. du vendeur 5475921
Quantité disponible : Plus de 20 disponibles
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. pp. 148. N° de réf. du vendeur 26128893465
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand pp. 148 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam. N° de réf. du vendeur 131694022
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND pp. 148. N° de réf. du vendeur 18128893459
Quantité disponible : 4 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Proper distribution of conditioned air in an air conditioning room is very important for comfort air conditioning to maintain the comfort parameters within a prescribed limit. Supply air outlets and return air locations affects the human comfort significantly by maintaining comfort parameters uniformly. Thus, the problem of finding the optimal arrangements of location of the supply air diffusers and return air outlets has been considered in this book. CFD through FLUENT is considered for analysis of the problem. Different arrangements of supply and return air points are considered for observing the comfort parameters like air temperature, air velocity, relative humidity in room air distribution so that the optimal arrangements can be evaluated where majority of the occupants present in the room feel comfortable. An experimental validation of the work is also performed to check the applicability of CFD in the analysis of room air distribution. This book will be helpful for the researchers using CFD as a tool for analysis of room air distribution with prototype experimentation validation so that the procedure can be applied to real life requirements.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 148 pp. Englisch. N° de réf. du vendeur 9783844383966
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Proper distribution of conditioned air in an air conditioning room is very important for comfort air conditioning to maintain the comfort parameters within a prescribed limit. Supply air outlets and return air locations affects the human comfort significantly by maintaining comfort parameters uniformly. Thus, the problem of finding the optimal arrangements of location of the supply air diffusers and return air outlets has been considered in this book. CFD through FLUENT is considered for analysis of the problem. Different arrangements of supply and return air points are considered for observing the comfort parameters like air temperature, air velocity, relative humidity in room air distribution so that the optimal arrangements can be evaluated where majority of the occupants present in the room feel comfortable. An experimental validation of the work is also performed to check the applicability of CFD in the analysis of room air distribution. This book will be helpful for the researchers using CFD as a tool for analysis of room air distribution with prototype experimentation validation so that the procedure can be applied to real life requirements. N° de réf. du vendeur 9783844383966
Quantité disponible : 1 disponible(s)