Optimization of the storage conditions for coagulation screening tests: at Advanced Medical and Dental Institute (AMDI) - Couverture souple

Ayesh, Sultan

 
9783847320791: Optimization of the storage conditions for coagulation screening tests: at Advanced Medical and Dental Institute (AMDI)

Synopsis

This study aims to determine the optimum storage temperature and time for Prothrombin time and activated Partial thromboplastin time at various intervals at both room temperature and refrigerator. This study was approved by the Ethics Committee of AMDI in USM. After obtaining the consent, 33 blood samples were collected from AMDI staff and students. Prothrombin time (PT) was measured at 0, 4, 8 and 24 hours (h). Partial thromboplastin time (APTT) was measured at 0, 2, 6 and 8 h both at room temperature (RT) and refrigerator. Thirty three subjects (14 males and 19 females, aged from 20 to 40 years) were involved. PT showed no significant differences at RT at 4 h, while significant differences after 8 h and 24 h at RT and after 4 h, 8 h and 24 h at refrigerator were observed. APTT showed no statistically significant differences at 2 h but showed significant differences at 6 h, 8 h at both RT and refrigerator. It can be concluded that samples for PT testing can be accepted only up to 4 h when kept at RT while the samples cannot be accepted when kept at refrigerator for 4 h and above. APTT samples can be accepted up to 2 h only at RT or refrigerator.

Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.

Présentation de l'éditeur

This study aims to determine the optimum storage temperature and time for Prothrombin time and activated Partial thromboplastin time at various intervals at both room temperature and refrigerator. This study was approved by the Ethics Committee of AMDI in USM. After obtaining the consent, 33 blood samples were collected from AMDI staff and students. Prothrombin time (PT) was measured at 0, 4, 8 and 24 hours (h). Partial thromboplastin time (APTT) was measured at 0, 2, 6 and 8 h both at room temperature (RT) and refrigerator. Thirty three subjects (14 males and 19 females, aged from 20 to 40 years) were involved. PT showed no significant differences at RT at 4 h, while significant differences after 8 h and 24 h at RT and after 4 h, 8 h and 24 h at refrigerator were observed. APTT showed no statistically significant differences at 2 h but showed significant differences at 6 h, 8 h at both RT and refrigerator. It can be concluded that samples for PT testing can be accepted only up to 4 h when kept at RT while the samples cannot be accepted when kept at refrigerator for 4 h and above. APTT samples can be accepted up to 2 h only at RT or refrigerator.

Biographie de l'auteur

Sultan Ayesh Mohammed is a medical laboratory specialist in Dar AL-Salam hospital and AL-Aqsa hospital, Yemen. He has master`s degree in Transfusion Sciences.

Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.