This book has been written based on PhD thesis. In this book, most fundamental dimensional analysis technique is used to develop some mathematical relationships to understand the flashover mechanism of contaminated insulator. The expression of time to flashover, flashover voltage in terms of ESDD and surface conductivity has been developed. In addition, the relationships between leakage resistance and ESDD, and ESDD and wind velocity have been developed. All mathematical models have been verified by the experiments.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
This book has been written based on PhD thesis. In this book, most fundamental dimensional analysis technique is used to develop some mathematical relationships to understand the flashover mechanism of contaminated insulator. The expression of time to flashover, flashover voltage in terms of ESDD and surface conductivity has been developed. In addition, the relationships between leakage resistance and ESDD, and ESDD and wind velocity have been developed. All mathematical models have been verified by the experiments.
He obtained his B. Sc., M. Sc. and PhD all in Electrical Engineering from CUET, Chittagong, BUET Dhaka and UTM, Malaysia respectively. He was a faculty member at CUET from 1994 to 2001. He then worked as an Assistant Professor in the ECE Department, College of Engineering, Sultan Qaboos University, Oman. Currently, he is a faculty member in the EEE
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. pp. 128. N° de réf. du vendeur 26128896133
Quantité disponible : 4 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Salam Md. AbdusHe obtained his B. Sc., M. Sc. and PhD all in Electrical Engineering from CUET, Chittagong, BUET Dhaka and UTM, Malaysia respectively. He was a faculty member at CUET from 1994 to 2001. He then worked as an Assistant P. N° de réf. du vendeur 5520654
Quantité disponible : Plus de 20 disponibles
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand pp. 128 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam. N° de réf. du vendeur 131691354
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND pp. 128. N° de réf. du vendeur 18128896143
Quantité disponible : 4 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book has been written based on PhD thesis. In this book, most fundamental dimensional analysis technique is used to develop some mathematical relationships to understand the flashover mechanism of contaminated insulator. The expression of time to flashover, flashover voltage in terms of ESDD and surface conductivity has been developed. In addition, the relationships between leakage resistance and ESDD, and ESDD and wind velocity have been developed. All mathematical models have been verified by the experiments. N° de réf. du vendeur 9783848416967
Quantité disponible : 2 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Modeling of Contaminated Insulator | Transmission line Insulator | Md. Abdus Salam | Taschenbuch | Englisch | LAP Lambert Academic Publishing | EAN 9783848416967 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 106602096
Quantité disponible : 5 disponible(s)