This book covers the seismic risk assessment of existing buildings based on hazard and vulnerability assessment. Hazard maps have been developed and vulnerability assessment of buildings was made by collecting inventory data and experimental study of typical existing buildings. Fragility curves for different types of buildings including single and double stories unreinforced brick masonry and concrete block masonry buildings, single, double and three stories confined brick masonry buildings, and double stories reinforced concrete buildings by using advanced capacity spectrum method (ACSM). Seismic risk has been established for all these buildings from hazard maps and corresponding fragility curves. The seismic risk determined from the hazard maps and fragility curves has been compared with the seismic risk calculated by using MAEviz software developed by Mid America Earthquake (MAE) Centre. It was found that Seismic risk for collapse prevention level is highest for unreinforced concrete block masonry buildings and similarly the seismic risk for confined brick masonry buildings is least. It was also concluded that the seismic risk for reinforced concrete buildings is minimum.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book covers the seismic risk assessment of existing buildings based on hazard and vulnerability assessment. Hazard maps have been developed and vulnerability assessment of buildings was made by collecting inventory data and experimental study of typical existing buildings. Fragility curves for different types of buildings including single and double stories unreinforced brick masonry and concrete block masonry buildings, single, double and three stories confined brick masonry buildings, and double stories reinforced concrete buildings by using advanced capacity spectrum method (ACSM). Seismic risk has been established for all these buildings from hazard maps and corresponding fragility curves. The seismic risk determined from the hazard maps and fragility curves has been compared with the seismic risk calculated by using MAEviz software developed by Mid America Earthquake (MAE) Centre. It was found that Seismic risk for collapse prevention level is highest for unreinforced concrete block masonry buildings and similarly the seismic risk for confined brick masonry buildings is least. It was also concluded that the seismic risk for reinforced concrete buildings is minimum. 408 pp. Englisch. N° de réf. du vendeur 9783848443123
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Shahzada KhanDr. Khan Shahzada completed his BSc study in Civil Engineering from University of Engineering and Technology Peshawar in 2003.He completed his MSc in Earthquake Engineering from Japan in 2007 and his PhD from UET Peshawa. N° de réf. du vendeur 5522552
Quantité disponible : Plus de 20 disponibles
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Seismic Risk Assessment of Buildings | Case Study Abbottabad City (Pakistan) | Khan Shahzada (u. a.) | Taschenbuch | 408 S. | Englisch | 2012 | LAP LAMBERT Academic Publishing | EAN 9783848443123 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 106495773
Quantité disponible : 5 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book covers the seismic risk assessment of existing buildings based on hazard and vulnerability assessment. Hazard maps have been developed and vulnerability assessment of buildings was made by collecting inventory data and experimental study of typical existing buildings. Fragility curves for different types of buildings including single and double stories unreinforced brick masonry and concrete block masonry buildings, single, double and three stories confined brick masonry buildings, and double stories reinforced concrete buildings by using advanced capacity spectrum method (ACSM). Seismic risk has been established for all these buildings from hazard maps and corresponding fragility curves. The seismic risk determined from the hazard maps and fragility curves has been compared with the seismic risk calculated by using MAEviz software developed by Mid America Earthquake (MAE) Centre. It was found that Seismic risk for collapse prevention level is highest for unreinforced concrete block masonry buildings and similarly the seismic risk for confined brick masonry buildings is least. It was also concluded that the seismic risk for reinforced concrete buildings is minimum.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 408 pp. Englisch. N° de réf. du vendeur 9783848443123
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book covers the seismic risk assessment of existing buildings based on hazard and vulnerability assessment. Hazard maps have been developed and vulnerability assessment of buildings was made by collecting inventory data and experimental study of typical existing buildings. Fragility curves for different types of buildings including single and double stories unreinforced brick masonry and concrete block masonry buildings, single, double and three stories confined brick masonry buildings, and double stories reinforced concrete buildings by using advanced capacity spectrum method (ACSM). Seismic risk has been established for all these buildings from hazard maps and corresponding fragility curves. The seismic risk determined from the hazard maps and fragility curves has been compared with the seismic risk calculated by using MAEviz software developed by Mid America Earthquake (MAE) Centre. It was found that Seismic risk for collapse prevention level is highest for unreinforced concrete block masonry buildings and similarly the seismic risk for confined brick masonry buildings is least. It was also concluded that the seismic risk for reinforced concrete buildings is minimum. N° de réf. du vendeur 9783848443123
Quantité disponible : 1 disponible(s)
Vendeur : Mispah books, Redhill, SURRE, Royaume-Uni
Paperback. Etat : Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book. N° de réf. du vendeur ERICA75838484431206
Quantité disponible : 1 disponible(s)