Nowadays, the number of heart attack patients is increasing day by day. Though it is tough to save heart attack patients, we can increase the statistics of saving the lives of those patients as well as the lives of those whom the heart attack patients are responsible for. The main design of this project is to track heart attack patients suffering a heart attack during driving, send them medical help and stop the vehicle they are driving to ensure that the persons along them are spared from accidents. An eye blinking sensor is used to monitor the eye blinking rate and a spO2 sensor is used to check the pulse rate of the patient. Both are connected to a micro controller. If eye blinking stops, then the signal is sent to the controller to make an alarm through the buffer. If the spO2 sensor perceives a variation in the pulse rate or low oxygen content in the blood, which may result in heart failure, then the controller stops the motor of the vehicle. Then, a Tarang F4 transmitter is used to sent the vehicle number and the mobile phone number of the patient to the nearest medical station within 25 km for medical aid. The pulse rate monitored via LCD .The Tarang F4 receiver acquires the signal and passes through the controller, the number gets displayed on the LCD screen and an alarm is produced through a buzzer as soon the signal is received. Five topics are discussed in this project: detecting the patient BPM and the eye blinking status; transmitting via Tarang F4 in case of abnormalities in the patient; the patient status is displayed and indicated by a buzzer; the hospital unit receives the patient's mobile phone number and car number and the communication between the vehicle and the hospital through Tarang F4.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : Lucky's Textbooks, Dallas, TX, Etats-Unis
Etat : New. N° de réf. du vendeur ABLING22Oct2817100641505
Quantité disponible : Plus de 20 disponibles
Vendeur : PBShop.store US, Wood Dale, IL, Etats-Unis
PAP. Etat : New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. N° de réf. du vendeur L0-9783960671954
Quantité disponible : Plus de 20 disponibles
Vendeur : PBShop.store UK, Fairford, GLOS, Royaume-Uni
PAP. Etat : New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. N° de réf. du vendeur L0-9783960671954
Quantité disponible : Plus de 20 disponibles
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Nowadays, the number of heart attack patients is increasing day by day. Though it is tough to save heart attack patients, we can increase the statistics of saving the lives of those patients as well as the lives of those whom the heart attack patients are responsible for. The main design of this project is to track heart attack patients suffering a heart attack during driving, send them medical help and stop the vehicle they are driving to ensure that the persons along them are spared from accidents. An eye blinking sensor is used to monitor the eye blinking rate and a spO2 sensor is used to check the pulse rate of the patient. Both are connected to a micro controller.If eye blinking stops, then the signal is sent to the controller to make an alarm through the buffer. If the spO2 sensor perceives a variation in the pulse rate or low oxygen content in the blood, which may result in heart failure, then the controller stops the motor of the vehicle. Then, a Tarang F4 transmitter is used to sent the vehicle number and the mobile phone number of the patient to the nearest medical station within 25 km for medical aid. The pulse rate monitored via LCD .The Tarang F4 receiver acquires the signal and passes through the controller, the number gets displayed on the LCD screen and an alarm is produced through a buzzer as soon the signal is received.Five topics are discussed in this project: detecting the patient BPM and the eye blinking status; transmitting via Tarang F4 in case of abnormalities in the patient; the patient status is displayed and indicated by a buzzer; the hospital unit receives the patient's mobile phone number and car number and the communication between the vehicle and the hospital through Tarang F4. 82 pp. Englisch. N° de réf. du vendeur 9783960671954
Quantité disponible : 2 disponible(s)
Vendeur : Ria Christie Collections, Uxbridge, Royaume-Uni
Etat : New. In. N° de réf. du vendeur ria9783960671954_new
Quantité disponible : Plus de 20 disponibles
Vendeur : Chiron Media, Wallingford, Royaume-Uni
PF. Etat : New. N° de réf. du vendeur 6666-IUK-9783960671954
Quantité disponible : 10 disponible(s)
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. pp. 84. N° de réf. du vendeur 26381401246
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand pp. 84. N° de réf. du vendeur 382469953
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND pp. 84. N° de réf. du vendeur 18381401236
Quantité disponible : 4 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Nowadays, the number of heart attack patients is increasing day by day. Though it is tough to save heart attack patients, we can increase the statistics of saving the lives of those patients as well as the lives of those whom the heart attack patients are r. N° de réf. du vendeur 385837015
Quantité disponible : Plus de 20 disponibles