This book describes the modification and characterization of carbon paste modified electrode for the detection of analytes such as Dopamine (DA), Ascorbic acid (AA), Uric acid (UA), Folic acid and Paracetamol in biological buffer solution. Dopamine (DA), 3, 4-dihydroxyphenylethylamine is an important naturally occurring neurotransmitter in the mammalian central nervous system. A deficiency in this catecholamine level can cause some serious diseases such as Parkinson, epilepsy and senile dementia in humans. Uric acid (UA) is the primary end product of purine metabolism in the human body. In a healthy human being, the typical concentration of UA in urine is around 2 mM and in the blood is in between 120 μM to 450 μM ranges. Electrochemical analysis on the modified electrodes represents a modern approach to electrode systems. They alter the electrode surface by means of a reagent placed on the electrode surface. Such deliberate alterations can thus meet these needs and can be beneficial to many electroanalytical problems. The work carried out in the above topic is divided and described into seven chapters.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book describes the modification and characterization of carbon paste modified electrode for the detection of analytes such as Dopamine (DA), Ascorbic acid (AA), Uric acid (UA), Folic acid and Paracetamol in biological buffer solution. Dopamine (DA), 3, 4-dihydroxyphenylethylamine is an important naturally occurring neurotransmitter in the mammalian central nervous system. A deficiency in this catecholamine level can cause some serious diseases such as Parkinson, epilepsy and senile dementia in humans. Uric acid (UA) is the primary end product of purine metabolism in the human body. In a healthy human being, the typical concentration of UA in urine is around 2 mM and in the blood is in between 120 miM to 450 miM ranges. Electrochemical analysis on the modified electrodes represents a modern approach to electrode systems. They alter the electrode surface by means of a reagent placed on the electrode surface. Such deliberate alterations can thus meet these needs and can be beneficial to many electroanalytical problems. The work carried out in the above topic is divided and described into seven chapters. 156 pp. Englisch. N° de réf. du vendeur 9786138946670
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: S R KIRAN KUMARDr. Kiran Kumar S R, obtained his doctorate degree chemistry from Kuvempu University of Mysore. Later joined K S Institute of Technology, Bangalore as an Assistant professor and in Started working in Centre for Nanomat. N° de réf. du vendeur 452471987
Quantité disponible : Plus de 20 disponibles
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26395128314
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 402297381
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18395128304
Quantité disponible : 4 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. MODIFIED ELECTRODES FOR ELECTROCHEMICAL SENSOR APPLICATIONS | METAL OXIDES MODIFIED ELECTRODES FOR ELECTROCHEMICAL SENSOR APPLICATIONS | Kiran Kumar S R (u. a.) | Taschenbuch | Englisch | 2020 | Scholars' Press | EAN 9786138946670 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 119561990
Quantité disponible : 5 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book describes the modification and characterization of carbon paste modified electrode for the detection of analytes such as Dopamine (DA), Ascorbic acid (AA), Uric acid (UA), Folic acid and Paracetamol in biological buffer solution. Dopamine (DA), 3, 4-dihydroxyphenylethylamine is an important naturally occurring neurotransmitter in the mammalian central nervous system. A deficiency in this catecholamine level can cause some serious diseases such as Parkinson, epilepsy and senile dementia in humans. Uric acid (UA) is the primary end product of purine metabolism in the human body. In a healthy human being, the typical concentration of UA in urine is around 2 mM and in the blood is in between 120 ¿M to 450 ¿M ranges. Electrochemical analysis on the modified electrodes represents a modern approach to electrode systems. They alter the electrode surface by means of a reagent placed on the electrode surface. Such deliberate alterations can thus meet these needs and can be beneficial to many electroanalytical problems. The work carried out in the above topic is divided and described into seven chapters.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 156 pp. Englisch. N° de réf. du vendeur 9786138946670
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book describes the modification and characterization of carbon paste modified electrode for the detection of analytes such as Dopamine (DA), Ascorbic acid (AA), Uric acid (UA), Folic acid and Paracetamol in biological buffer solution. Dopamine (DA), 3, 4-dihydroxyphenylethylamine is an important naturally occurring neurotransmitter in the mammalian central nervous system. A deficiency in this catecholamine level can cause some serious diseases such as Parkinson, epilepsy and senile dementia in humans. Uric acid (UA) is the primary end product of purine metabolism in the human body. In a healthy human being, the typical concentration of UA in urine is around 2 mM and in the blood is in between 120 miM to 450 miM ranges. Electrochemical analysis on the modified electrodes represents a modern approach to electrode systems. They alter the electrode surface by means of a reagent placed on the electrode surface. Such deliberate alterations can thus meet these needs and can be beneficial to many electroanalytical problems. The work carried out in the above topic is divided and described into seven chapters. N° de réf. du vendeur 9786138946670
Quantité disponible : 1 disponible(s)