A simple, accurate, and precise stability-indicating reverse phase high pressure liquid chromatographic method was developed and validated for the estimation of Perindopril arginine, Indapamide, and Amlodipine in the bulk and pharmaceutical dosage form. Chromatographic separation was carried out on ZORBAX RX C8 (250 mm × 4.6 mm, 5 µm) as a stationary phase with a mobile phase of gradient system of Phosphate Buffer with pH 2 containing Decane Sulphonate as ion-pairing agent (A) and Acetonitrile (B) at detection wavelength215 nm with flow rate 1.0 mL/min at column temperature 40 ºC. The tR of Perindopril, Indapamide, and Amlodipine was 31.39 ± 0.21 min, 25.73 ± 0.41min, and 36.95 ± 0.47 min, respectively. The method was linear over the concentration ranges 50-150 µg/ mL for Perindopril, 12.5-37.5 µg/ mL for Indapamide and 50-150 µg/ mL for Amlodipine. The LOD was 0.99 µg/ mL for Perindopril,0.87 µg/ mL for Indapamide and 3.99 µg/ mL for Amlodipine. The LOQ was3.02 µg/ mL for Perindopril, 2.6 µg/ mL for Indapamide and 12.08 µg/ mL for Amlodipine.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -A simple, accurate, and precise stability-indicating reverse phase high pressure liquid chromatographic method was developed and validated for the estimation of Perindopril arginine, Indapamide, and Amlodipine in the bulk and pharmaceutical dosage form. Chromatographic separation was carried out on ZORBAX RX C8 (250 mm × 4.6 mm, 5 µm) as a stationary phase with a mobile phase of gradient system of Phosphate Buffer with pH 2 containing Decane Sulphonate as ion-pairing agent (A) and Acetonitrile (B) at detection wavelength215 nm with flow rate 1.0 mL/min at column temperature 40 ºC. The tR of Perindopril, Indapamide, and Amlodipine was 31.39 ± 0.21 min, 25.73 ± 0.41min, and 36.95 ± 0.47 min, respectively. The method was linear over the concentration ranges 50-150 µg/ mL for Perindopril, 12.5-37.5 µg/ mL for Indapamide and 50-150 µg/ mL for Amlodipine. The LOD was 0.99 µg/ mL for Perindopril,0.87 µg/ mL for Indapamide and 3.99 µg/ mL for Amlodipine. The LOQ was3.02 µg/ mL for Perindopril, 2.6 µg/ mL for Indapamide and 12.08 µg/ mL for Amlodipine. 52 pp. Englisch. N° de réf. du vendeur 9786138968573
Quantité disponible : 2 disponible(s)
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26397278050
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 400180413
Quantité disponible : 4 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. A simple, accurate, and precise stability-indicating reverse phase high pressure liquid chromatographic method was developed and validated for the estimation of Perindopril arginine, Indapamide, and Amlodipine in the bulk and pharmaceutical dosage form. Chr. N° de réf. du vendeur 566150458
Quantité disponible : Plus de 20 disponibles
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18397278056
Quantité disponible : 4 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -A simple, accurate, and precise stability-indicating reverse phase high pressure liquid chromatographic method was developed and validated for the estimation of Perindopril arginine, Indapamide, and Amlodipine in the bulk and pharmaceutical dosage form. Chromatographic separation was carried out on ZORBAX RX C8 (250 mm × 4.6 mm, 5 µm) as a stationary phase with a mobile phase of gradient system of Phosphate Buffer with pH 2 containing Decane Sulphonate as ion-pairing agent (A) and Acetonitrile (B) at detection wavelength215 nm with flow rate 1.0 mL/min at column temperature 40 ºC. The tR of Perindopril, Indapamide, and Amlodipine was 31.39 ± 0.21 min, 25.73 ± 0.41min, and 36.95 ± 0.47 min, respectively. The method was linear over the concentration ranges 50-150 µg/ mL for Perindopril, 12.5-37.5 µg/ mL for Indapamide and 50-150 µg/ mL for Amlodipine. The LOD was 0.99 µg/ mL for Perindopril,0.87 µg/ mL for Indapamide and 3.99 µg/ mL for Amlodipine. The LOQ was3.02 µg/ mL for Perindopril, 2.6 µg/ mL for Indapamide and 12.08 µg/ mL for Amlodipine.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 52 pp. Englisch. N° de réf. du vendeur 9786138968573
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A simple, accurate, and precise stability-indicating reverse phase high pressure liquid chromatographic method was developed and validated for the estimation of Perindopril arginine, Indapamide, and Amlodipine in the bulk and pharmaceutical dosage form. Chromatographic separation was carried out on ZORBAX RX C8 (250 mm × 4.6 mm, 5 µm) as a stationary phase with a mobile phase of gradient system of Phosphate Buffer with pH 2 containing Decane Sulphonate as ion-pairing agent (A) and Acetonitrile (B) at detection wavelength215 nm with flow rate 1.0 mL/min at column temperature 40 ºC. The tR of Perindopril, Indapamide, and Amlodipine was 31.39 ± 0.21 min, 25.73 ± 0.41min, and 36.95 ± 0.47 min, respectively. The method was linear over the concentration ranges 50-150 µg/ mL for Perindopril, 12.5-37.5 µg/ mL for Indapamide and 50-150 µg/ mL for Amlodipine. The LOD was 0.99 µg/ mL for Perindopril,0.87 µg/ mL for Indapamide and 3.99 µg/ mL for Amlodipine. The LOQ was3.02 µg/ mL for Perindopril, 2.6 µg/ mL for Indapamide and 12.08 µg/ mL for Amlodipine. N° de réf. du vendeur 9786138968573
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. ESTIMATION OF PERINDOPRIL ARGININE, INDAPAMIDE AND AMLODIPINE BY HPLC | Bhamini Chaudhary (u. a.) | Taschenbuch | Englisch | 2022 | Scholars' Press | EAN 9786138968573 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 121284505
Quantité disponible : 5 disponible(s)