Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Six methods RP-HPLC, RP-HPTLC/densitometry and UV-Spectrophotometry (first order amplitude, first order AUC, second-order amplitude and second order AUC) have been developed for the determination of tadalafil in bulk and pharmaceutical formulation. RP-HPLC and RP-HPTLC/Densitometry methods are found to be accurate, precise, rugged and robust. Both these methods are adequately sensitive. The only limitation of RP-HPLC and RP-HPTLC/densitometry method is their cost. For RP-HPLC study, Design Expert software ver. 8.0.4 was used to study robustness parameter, which showed that method is robust. From results of ANOVA and analysis of response surfaces plots; it can be concluded that responses, y1 (Retention time) and y2 (Tailing factor) are robust for x1, x2, and x3; however, for y3(Theoretical plates) x1, x2, and x3 affect considerably. All four UV-Spectrophotometric methods are simple, accurate, precise and least calculations are involved for estimation of concentrations of the drug. No interference of the excipients was observed in any one of the methods during tablet assay. All the developed methods can be used for routine analysis of tadalafil in the pharmaceutical formulation. 104 pp. Englisch. N° de réf. du vendeur 9786139847150
Quantité disponible : 2 disponible(s)
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26387228123
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 392371716
Quantité disponible : 4 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Khan Zamir G.Mr. Zamir G Khan is working as Asst. Professor H. R. Patel Institute of Pharmaceutical Education & Research, Shirpur (M.S.) from 2014. He received his master degree in Pharmaceutical Chemistry in 2014 and Bachelor Degree. N° de réf. du vendeur 385874113
Quantité disponible : Plus de 20 disponibles
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18387228113
Quantité disponible : 4 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Six methods RP-HPLC, RP-HPTLC/densitometry and UV-Spectrophotometry (first order amplitude, first order AUC, second-order amplitude and second order AUC) have been developed for the determination of tadalafil in bulk and pharmaceutical formulation. RP-HPLC and RP-HPTLC/Densitometry methods are found to be accurate, precise, rugged and robust. Both these methods are adequately sensitive. The only limitation of RP-HPLC and RP-HPTLC/densitometry method is their cost. For RP-HPLC study, Design Expert software ver. 8.0.4 was used to study robustness parameter, which showed that method is robust. From results of ANOVA and analysis of response surfaces plots; it can be concluded that responses, y1 (Retention time) and y2 (Tailing factor) are robust for x1, x2, and x3; however, for y3(Theoretical plates) x1, x2, and x3 affect considerably. All four UV-Spectrophotometric methods are simple, accurate, precise and least calculations are involved for estimation of concentrations of the drug. No interference of the excipients was observed in any one of the methods during tablet assay. All the developed methods can be used for routine analysis of tadalafil in the pharmaceutical formulation. N° de réf. du vendeur 9786139847150
Quantité disponible : 1 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Six methods RP-HPLC, RP-HPTLC/densitometry and UV-Spectrophotometry (first order amplitude, first order AUC, second-order amplitude and second order AUC) have been developed for the determination of tadalafil in bulk and pharmaceutical formulation. RP-HPLC and RP-HPTLC/Densitometry methods are found to be accurate, precise, rugged and robust. Both these methods are adequately sensitive. The only limitation of RP-HPLC and RP-HPTLC/densitometry method is their cost. For RP-HPLC study, Design Expert software ver. 8.0.4 was used to study robustness parameter, which showed that method is robust. From results of ANOVA and analysis of response surfaces plots; it can be concluded that responses, y1 (Retention time) and y2 (Tailing factor) are robust for x1, x2, and x3; however, for y3(Theoretical plates) x1, x2, and x3 affect considerably. All four UV-Spectrophotometric methods are simple, accurate, precise and least calculations are involved for estimation of concentrations of the drug. No interference of the excipients was observed in any one of the methods during tablet assay. All the developed methods can be used for routine analysis of tadalafil in the pharmaceutical formulation.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 104 pp. Englisch. N° de réf. du vendeur 9786139847150
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Development of RP-HPLC, HPTLC and UV-Visible Spectrophotometry Methods | Zamir G. Khan (u. a.) | Taschenbuch | 104 S. | Englisch | 2018 | LAP LAMBERT Academic Publishing | EAN 9786139847150 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 114003177
Quantité disponible : 5 disponible(s)