The present work also investigates active protection of the steel embedded in concrete that is treated with surface bonded carbon FRP. The electrically conductive carbon fiber is used as anode while the reinforcing bar is used as cathode in the present active protection. Anodic current was passed through the reinforcement in both specimens to initiate cracking in concrete. Carbon FRP sheets have been adhesively bonded to the cylinders. The adhesive has been modified to impart electrical conductivity. Specimens were exposed to highly corrosive environment for specified times. Several performance metrics have been reported and the relative efficiency of active and passive protection have been studied. The active protection technique is very effective in retarding the corrosion of steel. However, an optimum current density must be maintained to avoid damages at the interfaces of steel and concrete.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
EUR 23 expédition depuis Allemagne vers Etats-Unis
Destinations, frais et délaisVendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The present work also investigates active protection of the steel embedded in concrete that is treated with surface bonded carbon FRP. The electrically conductive carbon fiber is used as anode while the reinforcing bar is used as cathode in the present active protection. Anodic current was passed through the reinforcement in both specimens to initiate cracking in concrete. Carbon FRP sheets have been adhesively bonded to the cylinders. The adhesive has been modified to impart electrical conductivity. Specimens were exposed to highly corrosive environment for specified times. Several performance metrics have been reported and the relative efficiency of active and passive protection have been studied. The active protection technique is very effective in retarding the corrosion of steel. However, an optimum current density must be maintained to avoid damages at the interfaces of steel and concrete. 128 pp. Englisch. N° de réf. du vendeur 9786139851980
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Singh Abhishek KumarAbhishek Kumar Singh and Honey Gaur both are working in Kalinga University, Raipur as an Assistant Professor in Civil Engineering Department. Both the faculties published many International Journal Papers and had . N° de réf. du vendeur 385874324
Quantité disponible : Plus de 20 disponibles
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. Neuware -The present work also investigates active protection of the steel embedded in concrete that is treated with surface bonded carbon FRP. The electrically conductive carbon fiber is used as anode while the reinforcing bar is used as cathode in the present active protection. Anodic current was passed through the reinforcement in both specimens to initiate cracking in concrete. Carbon FRP sheets have been adhesively bonded to the cylinders. The adhesive has been modified to impart electrical conductivity. Specimens were exposed to highly corrosive environment for specified times. Several performance metrics have been reported and the relative efficiency of active and passive protection have been studied. The active protection technique is very effective in retarding the corrosion of steel. However, an optimum current density must be maintained to avoid damages at the interfaces of steel and concrete.Books on Demand GmbH, Überseering 33, 22297 Hamburg 128 pp. Englisch. N° de réf. du vendeur 9786139851980
Quantité disponible : 2 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The present work also investigates active protection of the steel embedded in concrete that is treated with surface bonded carbon FRP. The electrically conductive carbon fiber is used as anode while the reinforcing bar is used as cathode in the present active protection. Anodic current was passed through the reinforcement in both specimens to initiate cracking in concrete. Carbon FRP sheets have been adhesively bonded to the cylinders. The adhesive has been modified to impart electrical conductivity. Specimens were exposed to highly corrosive environment for specified times. Several performance metrics have been reported and the relative efficiency of active and passive protection have been studied. The active protection technique is very effective in retarding the corrosion of steel. However, an optimum current density must be maintained to avoid damages at the interfaces of steel and concrete. N° de réf. du vendeur 9786139851980
Quantité disponible : 1 disponible(s)