In India, Power system for planning and operational purposes is divided into five regional grids. The synchronously connected NEW Grid comprising of the Northern, Western, Eastern, Southern and North-Eastern Grids. The All India demand met is of the order of 110,000 MW currently. There have been major grid disturbances on the 30th and the 31st July 2012 which have affected large parts of the Indian Electricity Grids. Due to high load and failure of monsoon, Northern Region was drawing a large quantum of power from neighboring Western and Eastern Grids whereas due to rains in Western Region demand was less and it was under drawing. This situation led to a much skewed load generation balance among the regions. A large quantum of power was flowing from the Western Grid to the Northern Grid directly as well as through the Eastern Grid and the system was under stress. Even if a lot of data was available, the operators at different control centers did not take the proper actions in time to prevent the blackouts. This depends partly on the reorganization of the control centers after the deregulation and partly on the lack of reliable decision support systems when the system is close to in
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26397283265
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 400142366
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18397283275
Quantité disponible : 4 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Vyas RajivRajiv Vyas has more than 5 years of experience in education sector, which includes diverse area of teaching, applied research and related consultancy services. He has done M.Tech in Power System. He is associated with JIET . N° de réf. du vendeur 385875604
Quantité disponible : Plus de 20 disponibles
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In India, Power system for planning and operational purposes is divided into five regional grids. The synchronously connected NEW Grid comprising of the Northern, Western, Eastern, Southern and North-Eastern Grids. The All India demand met is of the order of 110,000 MW currently. There have been major grid disturbances on the 30th and the 31st July 2012 which have affected large parts of the Indian Electricity Grids. Due to high load and failure of monsoon, Northern Region was drawing a large quantum of power from neighboring Western and Eastern Grids whereas due to rains in Western Region demand was less and it was under drawing. This situation led to a much skewed load generation balance among the regions. A large quantum of power was flowing from the Western Grid to the Northern Grid directly as well as through the Eastern Grid and the system was under stress. Even if a lot of data was available, the operators at different control centers did not take the proper actions in time to prevent the blackouts. This depends partly on the reorganization of the control centers after the deregulation and partly on the lack of reliable decision support systems when the system is close to in. N° de réf. du vendeur 9786139880362
Quantité disponible : 2 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Load flow analysis of grid disturbance | Rajiv Vyas (u. a.) | Taschenbuch | Englisch | LAP Lambert Academic Publishing | EAN 9786139880362 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 114731981
Quantité disponible : 5 disponible(s)