Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book will helpful to the students of cryogenic engineering who are working on Pulse Tube Refrigeration Technology. Objective of the work is to analyze the pulse tube refrigeration process with the help of CFD. To validate CFD methodology by comparing experimental data. To optimize pulse tube refrigeration process by changing geometrical parameters like length and diameter of the inertance tube and valve opening/closing time and operating condition like frequency and mesh size of the regenerator material. The lowest temperature 209.5 K achieved at 1.4 mm diameter and 1 meter length of inertance tube with 0.6/0.4 valve opening/closing time with 300 mesh size of regenerator material at 1.8 Hz operating frequency. 104 pp. Englisch. N° de réf. du vendeur 9786139935147
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Parmar NimeshkumarProf. Parmar N. B. is working as a Assistant Professor atDepartment of Farm Machinery and Power Engineering at Collegeof Agricultural Engineering and Technology,Junagadh Agricultural University, Junagadh (Gujarat),I. N° de réf. du vendeur 260897978
Quantité disponible : Plus de 20 disponibles
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book will helpful to the students of cryogenic engineering who are working on Pulse Tube Refrigeration Technology. Objective of the work is to analyze the pulse tube refrigeration process with the help of CFD. To validate CFD methodology by comparing experimental data. To optimize pulse tube refrigeration process by changing geometrical parameters like length and diameter of the inertance tube and valve opening/closing time and operating condition like frequency and mesh size of the regenerator material. The lowest temperature 209.5 K achieved at 1.4 mm diameter and 1 meter length of inertance tube with 0.6/0.4 valve opening/closing time with 300 mesh size of regenerator material at 1.8 Hz operating frequency. N° de réf. du vendeur 9786139935147
Quantité disponible : 1 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book will helpful to the students of cryogenic engineering who are working on Pulse Tube Refrigeration Technology. Objective of the work is to analyze the pulse tube refrigeration process with the help of CFD. To validate CFD methodology by comparing experimental data. To optimize pulse tube refrigeration process by changing geometrical parameters like length and diameter of the inertance tube and valve opening/closing time and operating condition like frequency and mesh size of the regenerator material. The lowest temperature 209.5 K achieved at 1.4 mm diameter and 1 meter length of inertance tube with 0.6/0.4 valve opening/closing time with 300 mesh size of regenerator material at 1.8 Hz operating frequency.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 104 pp. Englisch. N° de réf. du vendeur 9786139935147
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. CFD Simulation of Single Stage PTR using Standard Commercial Software | Nimeshkumar Parmar (u. a.) | Taschenbuch | 104 S. | Englisch | 2018 | LAP LAMBERT Academic Publishing | EAN 9786139935147 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu. N° de réf. du vendeur 115099293
Quantité disponible : 5 disponible(s)